Tandberg Data MSERIES FC USER Скачать руководство пользователя страница 4

Tandberg Data FC420 Bridge Option User’s Guide
Document T6423053-01, Ver. 1, Rel. 0
November 2002

4

Cabling the M2500 Library for Fibre Channel

Cabling the M2500 Library for Fibre Channel

0

The cabling configuration used for the M2500 library with the FC420 

option depends on the following factors:
• Number of tape drives installed
• Tape  drive  type  (SDLT  or  LTO)
• Number of FC420 Fibre bridges installed
• Data transfer rate of the storage area network (SAN)

One- and Two-Drive 
Library Cabling

0

If the M2500 library has only one or two tape drives, the cabling is the 

same regardless of drive type or SAN. One- or two-drive libraries only 

require one FC420 Fibre bridge.

Figure 1

 shows the cabling for a one-drive library.

Figure 1  One-Drive 
Cabling

As shown in the figure, a SCSI daisy chain is established from one of 

the SCSI ports on the FC420 to the SCSI controller and then to drive 0, 

where the daisy chain is terminated. The SCSI controller is included in 

the chain to pass SCSI commands to the robot.
The SCSI controller and drive 1 must be on the same SCSI bus because 

the SCSI controller has termination disabled.

Drive 1

Slot for FC420

Slot for FC420

FC420

SCSI controller

SCSI

SCSI

SAN

Fibre

M2500

Auxiliary
electronics
module

Primary
electronics
module

Terminator

Содержание MSERIES FC USER

Страница 1: ...e M2500 Library for Fibre Channel 4 One and Two Drive Library Cabling 4 Cabling with Three or More Drives 5 Setting SCSI IDs 7 Configuring FC420 Firmware 8 Setting Up an Ethernet Connection 8 Verifyin...

Страница 2: ...dge Option User s Guide Document T6423053 01 Ver 1 Rel 0 November 2002 2 6207947 04fN 13 FC420 Services Software Commands 13 FC420 Service Software Operation 13 Command Syntax 14 List of Abbreviations...

Страница 3: ...a transfer architecture for use with computers and mass storage devices Fibre Channel is rapidly emerging to challenge SCSI as the interface of choice for host to storage applications Fibre Channel ad...

Страница 4: ...drives the cabling is the same regardless of drive type or SAN One or two drive libraries only require one FC420 Fibre bridge Figure 1 shows the cabling for a one drive library Figure 1 One Drive Cabl...

Страница 5: ...vailable to each tape drive Cabling with Three or More Drives 0 When cabling M2500 libraries with three or more tape drives you need to know the type of tape drive installed in the library and the dat...

Страница 6: ...re 3 One Drive Per FC420 Port Cabling SDLT LTO Drive Cabling with a 2 GB SAN 0 If the M2500 library with SDLT or LTO drives is connected to a 2 GB SAN Tandberg Data recommends a maximum ratio of 2 tap...

Страница 7: ...IDs for the library Table 1 SCSI ID Settings Note To increase the bandwidth available to each tape drive install additional FC420 Fibre bridges and use the cabling configuration shown in figure 3 Dev...

Страница 8: ...lly connected to which Fibre Channel ports on the FC420 board The major steps for configuring FC420 Fibre bridge firmware involve Setting Up an Ethernet Connection Verifying Current FC420 Firmware on...

Страница 9: ...ick the Specify an IP address option button The IP Address Subnet Mask and Gateway fields become active f Type 10 0 0 x where x is a number between 2 and 253 in the IP Address field 255 255 255 0 in t...

Страница 10: ...local echo mode type set SerialPortEcho enabled at the Ready prompt and then press Enter Scanning the SCSI buses on the Library 0 Use the following procedure to confirm that the SCSI buses are cabled...

Страница 11: ...tes 3 When the Ready prompt reappears type saveconfiguration and press Enter 4 When the Ready prompt reappears type firmwarerestart and press Enter Making Other Configuration Changes 0 The preceding f...

Страница 12: ...Up an Ethernet Connection on page 8 3 From the computer open a command prompt window and type ftp FC420 IP address and then press Enter 4 When prompted for a username type sysadmin or the current syst...

Страница 13: ...value of a parameter or setting This command may be abbreviated to g Set changes the value of a parameter or setting This command may be abbreviated s and does not take effect until a SaveConfigurati...

Страница 14: ...Services Software commands is shown in table 1 Table 2 Most Common FC420 Services Commands Command Description Default Syntax AutoMap Immediate Automatically maps all currently operational SCSI device...

Страница 15: ...Fh for the mask event_level switch mask that controls what reporting level events are displayed The mask is a byte value with the following bit patterns corresponding to the currently supported report...

Страница 16: ...current speed of the connection is indicated in parentheses in the response to the get ethernetspeed command auto set ethernetspeed 10 100 auto get ethernetspeed Exit Immediate Exits the current Teln...

Страница 17: ...tiator enabled disabled get fcinitiator FcPortList Immediate Lists the available Fibre Channel ports and their current status fcportlist Fcp2 Enables disables the Fibre bridge s compliance with the FC...

Страница 18: ...he Fibre port number set fcwwname portnumber 0xnn 0xnn 0xnn get fcwwname portnumber FibreBridgeModel Reports the specific FC420 model information get fibrebridgemodel FibreBridgeName Specify the 8 cha...

Страница 19: ...he current IP gateway assigned by the nameserver 0 0 0 0 set ipgateway xxx xxx xxx xxx get ipgateway IPSubnetMask Sets displays the current subnet mask If the ipdhcp command is enabled the get command...

Страница 20: ...egrees C 5 40 degrees C 70 C set maxencltempalrm 5 40 get maxencltempalrm Menu Enables disabled the menu interface Entering the command alone without parameters toggles the current state menu enabled...

Страница 21: ...RELEASED status since it may issue set commands reserve RestoreConfiguration Immediate Restore to factory default configuration or the last saved configuration The new configuration must be saved to...

Страница 22: ...sb ScsiPortResetOnStartup Specify whether the SCSI port should be reset on power up enabled set scsiportresetonstartup sb enabled disabled get scsiportresetonstartup sb ScsiPortSelTimeout Show the tim...

Страница 23: ...nterface CLI session with a given host This information is taken from NVRAM Any map coinciding with a user specified ServicesLUN must first be set to offline before attempting to change the ServicesLU...

Страница 24: ...a SCSI device selection time out or busy event disabled set virtualdriveresponse enabled disabled get virtualdriveresponse XCDevices Displays information about the devices used in a specified Extended...

Страница 25: ...opy commands issued to the Fibre bridge Each Extended Copy command is identified with a unique number This number called cmdnumber is used when invoking the xcdevices and xcerror commands get xcstatus...

Страница 26: ...Tandberg Data FC420 Bridge Option User s Guide Document T6423053 01 Ver 1 Rel 0 November 2002 26 FC420 Services Software Commands...

Отзывы: