Tandberg Data FC420 Bridge Option User’s Guide
Document T6423053-01, Ver. 1, Rel. 0
November 2002
20
FC420 Services Software Commands
LogEvent
Sets the switches which control the
filtering performed when logging
events. The switches have the
following meanings and settings:
[enabled | disabled]
switch: controls
whether or not events logging is
enabled or disabled.
[
subsystem
]
switch: same as switch for
DispEvent in previous section
[
event_level
]
switch: same as switch
for DispEvent in previous section
[
status
]
switch: same as switch for
DispEvent in previous section
disabled
3Fh
3Fh
all
set logevent [enabled |
disabled] | [[
subsystem
]
[
event_level
] [
status
]]
get logevent
MaxEnclTempAlrm
Sets/displays the maximum enclosure
temperature alarm of the unit in
degrees C (5-40 degrees C).
70°C
set maxencltempalrm [5 - 40]
get maxencltempalrm
Menu
Enables/disabled the menu interface.
Entering the command alone without
parameters toggles the current state.
menu <[enabled | disabled]>
MinEnclTempAlrm
Sets/displays the minimum enclosure
temperature alarm of the unit in
degrees C (5-40 degrees C).
0°C
set minencltempalrm [5 - 40]
get minencltempalrm
OEMConfigFile
Reports the name (i.e., the contents of
the first record) of the OEM
configuration file stored in persistent
memory. This file is used to override
the factory default configuration of the
FC420 Fibre bridge.
get oemconfigfile
ParityLog
Resets/displays the parity error
statistics for the Fibre bridge. The
get
command displays the statistics; the
set
command resets the statistic
counters to zero.
set paritylog clear
get paritylog
Performance
Returns the performance data for a
user-specified Fibre port.
get performance <
fp
>
Command
Description
Default
Syntax