Tandberg Data FC420 Bridge Option User’s Guide
Document T6423053-01, Ver. 1, Rel. 0
November 2002
10
Configuring FC420 Firmware
Figure 5 Telnet Window
Showing Connection with
FC420
Verifying Current
FC420 Firmware
0
The Telnet connection window shows the firmware version and gives
the firmware revision date. See
figure 5
.
Use this information to determine if the FC420 Fibre bridge has current
firmware.
Setting Local Echo
Mode
0
To set local echo mode, type
set SerialPortEcho enabled
at the
Ready
prompt and then press
<Enter>
.
Scanning the SCSI
buses on the Library
0
Use the following procedure to confirm that the SCSI buses are cabled
properly.
1
At the
Ready
prompt, type
scsitargets 0
, and then press
<Enter>
.
This command scans and displays all SCSI devices found on SCSI
bus 0.
2
When the
Ready
prompt reappears, type
scsitargets 1
, and then
press
<Enter>
if the second SCSI port on the FC420 bridge is being
utilized.
Note:
If you suspect that the firmware needs to be updated, follow
the instructions found in
Updating FC420 Firmware
on
page 12.
Firmware version
information