1 4 8
T A L K S W I T C H U S E R G U I D E • N O R T H A M E R I C A
4. File -> Save to TalkSwitch
Figure 113: Save settings
When storing the CDR to a file on TalkSwitch, approximately 6000 records
are stored in a circular buffer. This means that after about 6000 records, the
oldest ones will be deleted and new ones are created. On a very busy system,
6000 records may only cover a couple of days, but on a system with less
traffic, 6000 records may cover more than a month.When the CDR data is
streaming real-time from the Serial port, there is no buffer limit and no file
is generated on TalkSwitch. When a call event is completed, the record is
sent through Serial port.
4.2 RETRIEVING DATA
There are 2 different methods for retrieving the data from TalkSwitch:
•
Web Interface
—
Store to File on TalkSwitch.
(48-CA and 48-CVA models)
•
Serial Interface
—
Real-time to Serial Port
While the TalkSwitch configuration software displays two options for
Call
Logging Output,
only the available option can be selected.
4.2.1 Web interface — Store to File on TalkSwitch
You can access the CDR information through a web interface as follows:
1. Enter the unit IP address in the
Address
field of a web browser.
2. Enter the system name in the
User Name
field and the administrator
password in the
Password
field.
Select
System Information -> IP Configuration
in the configuration
software to find the unit’s IP address.