To trim thread
77
1
2
3
4
5
6
7
8
9
10
11
Chapter 5
PT10
2-3.
To change thread breakage detecting sensitivity (Thread Detection)
Use this function in the following cases.
(1)
Thread breakage is detected even when thread is not broken.
(2)
Thread breakage detection timing is late.
2-3-1.
Explanation on the screen
[a]
Setting how many consecutive times of detection of upper thread breakage are regarded as
thread breakage
0: Not to stop even if upper thread is broken
N: To stop if upper thread is broken (the detecting sensitivity differs
in each needle bar) (p.101)
1, 2, 3, 4: To stop if upper thread is broken (Detecting sensitivity is same in all needle
bar)
When selecting "3", the thread breakage will be detected after upper thread breaks three
times continuously.
The relationship between the number of detecting times and sensitivity is shown as follows.
[b]
Setting how many consecutive times of detection of "under thread (ratio)" are regarded thread
breakage to stop the machine
0: Not to stop even if under thread is broken
N: To stop if under thread is broken (the detecting sensitivity differs
in each needle bar) (p.101)
2, 4, 6, 8: To stop if under thread is broken (Detecting sensitivity is same in all needle
bar)
When selecting "4", the thread breakage will be detected after upper thread breaks four
times continuously.
The relationship between the number of detecting times and sensitivity is shown as follows.
F2
N
6 Thread Detection
0/1/2/3/4
70
Upper thread
Under (Unit)
Under (Step Ratio)
4
0/2/4/6/8
30 100
[%]
[b]
[c]
[a]
Number of upper thread breakage detecting times
Number of under thread breakage detecting times
Sensitivity of [b] described above
1
High
4
Low
2
3
[Sensitivity]
2
High
8
Low
4
6
[Sensitivity]
Содержание TEMX-C Series
Страница 13: ...To search from the menu key ...
Страница 25: ...Inspection before starting work 12 Chapter 1 ...
Страница 39: ...How to use each part 26 Chapter 2 ...
Страница 40: ... E 1 2 3 4 5 6 7 8 9 10 11 27 PT10 Chapter 3 Screen 1 Screen display 28 2 Message display 31 ...
Страница 104: ...To stop the machine 91 1 2 3 4 5 6 7 8 9 10 11 Chapter 5 PT10 4 To make Frame Limit Setting effective YES ...
Страница 147: ...Other functions that must be remembered 134 Chapter 5 ...
Страница 171: ...To move the frame to the position registered 158 Chapter 6 ...
Страница 189: ...Design stored in USB memory 176 Chapter 7 ...
Страница 204: ...Functions concerning optional device 191 1 2 3 4 5 6 7 8 9 10 11 Chapter 8 4 To use air compressor YES RR07 ...