Countermeasure when the machine stopped
197
1
2
3
4
5
6
7
8
9
10
11
Chapter 9
QS07
1-3.
Stop due to malfunction
It is displayed in red on the screen. It is caused by card, harness or communication error. If the below code
No. is displayed, consult the distributor.
B04 USB memory is not inserted.
Insert.
BC1 Design tried to input is not in design spooler.
Check the condition of design spooler.
BC2 The same file name exists in USB memory.
Change the file name.
BC5 Insufficient remaining capacity of USB memory
Replace with a USB memory with enough
remaining capacity.
BF1
At network connection to host PC, IP address
was not obtainable from DNS server.
Check IP address of DNS server. Correct “IP
Setting.ini” file. Check operating condition of
DNS server.
BF2
The contents of “IP Setting.ini” file for network
setting was incorrect
Correct the contents of “IP Setting.ini” file.
5B1
It is not possible to input data due to abnormal
contents of configuration in TCF design.
Check the design.
5C1
Data set was performed without frame origin
memory after installation of software.
The machine was stopped during operation of
frame origin memory.
Perform frame origin memory. (p.148)
5C2
Machine was started during moving up/down of
sequin device.
Start the device after completion of up/down.
5C3 Setting error of sequin device III
Check the setting of panel.
5C6 General external device is operating.
Operate the machine after general external
device is stopped.
No.
Stop Factor
How to restore
311
Encoder A signal does not change for 5 seconds.
Check encoder or encoder signal lines. Check
excitation of the main shaft driver.
Abnormality of motor, motor belt
Check the motor or motor belt.
312
Encoder Z signal does not change (TFMX,
TFMS). Fixed position signal (Main shaft Z
signal) does not change during operation (TEMX-
C).
Press the E key.
Check the encoder or encoder signal lines.
No.
Stop Factor
How to restore
Information error of head number
The setting conflicts with the actual
number of connection.
[3C3]
"Reset" >>E
Code No.
Stop Factor
Содержание TEMX-C Series
Страница 13: ...To search from the menu key ...
Страница 25: ...Inspection before starting work 12 Chapter 1 ...
Страница 39: ...How to use each part 26 Chapter 2 ...
Страница 40: ... E 1 2 3 4 5 6 7 8 9 10 11 27 PT10 Chapter 3 Screen 1 Screen display 28 2 Message display 31 ...
Страница 104: ...To stop the machine 91 1 2 3 4 5 6 7 8 9 10 11 Chapter 5 PT10 4 To make Frame Limit Setting effective YES ...
Страница 147: ...Other functions that must be remembered 134 Chapter 5 ...
Страница 171: ...To move the frame to the position registered 158 Chapter 6 ...
Страница 189: ...Design stored in USB memory 176 Chapter 7 ...
Страница 204: ...Functions concerning optional device 191 1 2 3 4 5 6 7 8 9 10 11 Chapter 8 4 To use air compressor YES RR07 ...