background image

C o r a l

Te r m i n a l E q u i p m e n t -

F l e x S e t
I n s t a l l a t i o n M a n u a l

D i g i t a l S t a t i o n

1 2 0 , 1 2 0 D , 1 2 0 L , 1 2 0 S , 1 2 1 S , 2 8 0 , 2 8 0 D , 2 8 0 D - Z , 2 8 0 S , 2 8 1 S , F l e x A P D L a n d C PA

TM

International Headquarters
Tadiran Telecom Ltd.
18 Hasivim Street P.O.Box 7607
Petach Tikva 49170 Israel
Tel. +972-3-9262000, Fax. +972-3-9262310

http://www.tadirantele.com

USA Headquarters
Tadiran Telecom, Inc.
4 Tri Harbor Court
Port Washington, NY 11050
Tel. +1-516-632-7200, Fax. +1-516-632-7210

(GLWLRQ2FW

Содержание FlexSet 280

Страница 1: ...Digital Station Terminal Equipment Installation Manual FlexSet 280 280D 280D Z 280S 281S FlexAPDL PEX APA and CPA 120 120D 120L 120S 121S Creating a new world of IPportunities Edition 4 1...

Страница 2: ...or liability to make changes in equipment design or specifications Information supplied by the Manufacturer is believed to be accurate and reliable However no responsibility is assumed by the Manufact...

Страница 3: ...evation Position 1 8 Database Programming 1 9 General System Parameters Applied to all Keysets in the System 1 9 Possible Group Assignments 1 11 Parameters applied to each keyset 1 11 Personalizing th...

Страница 4: ...Wall Mount Desk Elevation Wall Mount 3 2 Wall Mounting Using Wall Socket 3 6 Desk Elevation Bracket 28 degree 3 8 Desk Elevation Stand 60 degree 3 11 4 FlexSet PEX F PEX FS Installation Overview 4 1 P...

Страница 5: ...APA FS Installation Overview 6 1 Preparing for Installation 6 2 Inspect for Damage 6 2 Unpacking the Shipping Container 6 2 Installing 6 4 To Install a PEX APA Module in an Existing FlexSet 280 281 Un...

Страница 6: ...nstallation When to Use an External Power Supply 8 2 Single Unit Power Supply 8 3 Powering Multiple Units over the LAN 8 3 9 FlexAPDL Installation Overview 9 1 Preparing for Installation 9 2 Inspect f...

Страница 7: ...nnect the CPA to the Coral via a Standard Wall Socket 10 8 To Connect the CPA to the External Speaker 10 9 To Connect the Relay Contacts 10 9 External Power Supply 10 9 Wall Mount Position 10 10 Volum...

Страница 8: ...tibility 6 1 Coral FlexSet 40B Capabilities and Pre Installation Requirements 7 4 External Power Requirements 8 1 When to use an External Power Supply 8 2 FlexAPDL Compatibility 9 1 Maximum Line Lengt...

Страница 9: ...ll Socket 3 6 Desktop Elevation Rubber Bumpers 3 8 Fitting the Desktop Elevation Bracket FlexSet 280x 3 9 Fitting the Desktop Elevation Bracket FlexSet 120x 3 9 Completed Desktop Elevation 28o 3 10 Fl...

Страница 10: ...ng Piece 7 8 FlexSet 280 With 3 FlexSet 40Bs Attached Bottom View 7 9 Coral FlexSet 280 with six FlexSet 40Bs Attached Bottom View 7 10 115 230VAC TPS Telephone Power Supply 8 3 RJ 11 Pin Assignments...

Страница 11: ...it Coral FlexiCom 200 Base Unit Coral FlexiCom 200 Expansion Unit Coral FlexiCom 300 400 5000 Coral FlexiCom 6000 All keyset types Database Programming Program Interface and Database Reference Manual...

Страница 12: ...inel FlexIP SoftPhone FLIPS DKT DST DPEM Installation and how to use See Table 12 1 Related Documentation for DKT DST DPEM Terminals FlexAir Handset Installation and description See Table 13 1 Related...

Страница 13: ...er necessary to keep the empty cartons Dispose of it in accord with local regulations Unpacking the Shipping Container The following items should be present in the box containing the FlexSet telephone...

Страница 14: ...so for the Coral FlexSet 121S and 281S respectively FlexSet 121S and 280S models are identical to 120S and 280S models except that they require Coral software version 15 5 and above FlexAPDL FlexSet 1...

Страница 15: ...In the following sections the 8SFTsl 16SFTsl and 8F8Ssl cards are used in Coral FlexiCom 200 and CDRS 200 systems and 8SFTipx and 16SFTipx are used in the Coral IPx 500 and CDRS 200E systems All othe...

Страница 16: ...DC resistance of the loop be 200 Ohms or less 175 Ohms for FlexSet 80 or GKT Maximum line lengths from 8 16 24 SFT 8 16 24 SFT Office 4 8 SA8F Office 4 8 SA16F Office 8 16 SFTipx 8 16 SFTsl and 8F8Ssl...

Страница 17: ...ht 31oz 878gr FlexSet 120L 3 3in 8 5cm 11 2in 28 5cm 8 7in 22cm Weight 42 7oz 1210gr FlexSet 280D Z 3 3in 8 5cm Weight APA 6 13oz 174gr Weight PEX APA 7 7oz 217gr Weight PEX 7 54oz 214gr APA F PEX FS...

Страница 18: ...igure 1 3 and Figure 1 4 Place either end of the telephone line cord into this socket The cord comes with the same connector type on both ends The connector will fit properly in one direction only If...

Страница 19: ...ve the protective tab Discard the tab in accordance with local regulations The purpose of the tab is to avoid continuous pressure on the cradle rubber pad in the off hook position during shipping and...

Страница 20: ...g a single unit power supply insert the TPS Telephone Power Supply plug into the jack marked DC on the rear of the FlexSet base on those telephones equipped with PEX or PEX APA The TPS is provided sep...

Страница 21: ...24SFT card supports up to 24 keysets Verify that System Sizes allocates sufficient resources to accommodate the total number of FlexSets provided by all cards installed in the system If insufficient...

Страница 22: ...Route SKEY This option allows to define up to 15 Soft key sets and to assign a particular set to a station or a range of stations Each set includes a list of features by number in the order entered b...

Страница 23: ...one Pickup Group Bell UNA Group Route BELL Zoned Voice Page Group Route VPZ Group Call Route CALL Parameters applied to each keyset The following parameters of the system database are used to assign i...

Страница 24: ...n___________________________________________ Route KEY An operating profile for each keyset is defined in the keyset definition This profile assigns the keyset two COS levels that can be imposed durin...

Страница 25: ...FlexSet 120 120L 120D 22 FlexSet 280S 281S or 24 FlexSet 280 280D 280D Z user programmable buttons and 4 additional buttons These additional buttons are programmed system wide by the system administer...

Страница 26: ...nated for the specific FlexSet model refer to the table below Table 1 2 Label Sheet Catalog Use DESI software downloaded from the manufacturer s site or from the DESI site http www desi com to print t...

Страница 27: ...ESI Lite menu choose File Print The left column on the multi designation label is intended for the four system defined fixed keys Other columns are intended for the programmable speed dial keys 5 To a...

Страница 28: ...B Top Plate Removal Programming the Buttons To program a button directly from the telephone keyset refer to the relevant user guide for your FlexSet User programmable buttons can also be programmed fr...

Страница 29: ...abel on the bottom of the keyset When plugging in the phone the left hand side of the LCD display will show the following as a function of version for a short time prior to initialization FlexSet 121S...

Страница 30: ...ty 2 Keysets and Card Compatibility Model Name 8SVD 8SKD 16SKD 8SDT 16SDT 24SDT 8 16SDTsl 8D8Ssl 8 16 24SFT 8 16SFTipx 8 16 24SFT Office 4 8SA8F Office 4 8SA16F Office 4 8S8F Office 4 8S16F Office 8 1...

Страница 31: ...15 or lower the bottom line in the telephone display will not appear and the soft key functions will not be available The FlexSet 121S and 281S models will function in the same manner as the FlexSet...

Страница 32: ...RAM or EPROM will be discovered several seconds after the start of normal operation The normal initialization procedure includes 4 essential steps listed below Step 1 Initialization of Hardware and Me...

Страница 33: ...for several minutes and then disappear The message can also appear in cases when there are abnormally high amounts of electromagnetic interference This causes the signal to noise ratio to be too low f...

Страница 34: ...to the Keyset is supplied by the Peripheral Card the display will show a single character according to the version as listed in Distinguishing the Various Keyset Versions on page 2 1 above as soon as...

Страница 35: ...same for telephones with an LCD display and for those without the display The only difference is the presence or absence of the display In order to carry out the procedure 1 Remove the telephone line...

Страница 36: ...lephones with a display the following message will appear where XY is an internal hexadecimal number Volume Button To test the volume up down button only on telephones with a display 5 Press the up or...

Страница 37: ...ill not work in PF mode 2 The FlexSet will be ruined by incoming ring voltage on the PF trunk 3 When the Coral resets and comes back on line the FlexSets wired for power fail operation will never init...

Страница 38: ...ected to one of the cards listed above the following message will appear on the display and remain there for 10 seconds This message is then overwritten by the following This is a definite sign that t...

Страница 39: ...l 8D8Ssl 8 16 SKD and 8SVD the following message will appear on the display and remain there for 10 seconds This message is then overwritten by the following In order to help identify this situation t...

Страница 40: ...atch Errors Table 2 4 Display Size Coral Version 15 or higher Table 2 5 Display Size Coral Version 14 67 and below Table 2 3 Display Size Mismatch Errors Table 2 4 Display Size Coral Version 15 or hig...

Страница 41: ...Entry Type Description 0 No display FlexSet 120 120L DST ADPL CPA 2 DSP48 FlexSet 120D 2 rows x 24 characters FlexSet 120S 3 rows x 24 characters 3 DSP80 FlexSet 280D 280D Z 2 rows x 40 ch FlexSet IP...

Страница 42: ...another one If the other one does not initialize it is recommended to connect the original telephone directly to the MDF If this does not help try to initialize the 8 16 24 SFT 8 16 24 SFT Office 4 8...

Страница 43: ...e FlexSet is then snapped onto the bracket The wall mount elevation bracket may be reversed on a desktop to elevate the rear of the FlexSet on a desktop a twenty eight degree angle lowering the viewin...

Страница 44: ...2 rubber bumpers The rubber bumpers screws and wall plugs included are not used when desk mounting Figure 3 1 Wall Mounting Bracket B Wall Mounting The FlexSet is easily wall mounted with an optional...

Страница 45: ...ough to allow the wall plugs to enter snugly 4 Insert the three wall plugs into the holes 5 Insert the three screws into the wall plugs and partially tighten them to the wall taking care to leave enou...

Страница 46: ...ts on the bottom of the phone A towards bottom legs of the bracket and snap them in place as shown in Figure 3 4 11 Snap the legs located on the top of the bracket into the matching slots B at the top...

Страница 47: ...ace the handset see Figure 3 5 The rotated handset hook secures the handset in an upright position Figure 3 5 Handset hook Figure 3 6 Side View Completed Wall Mount Place Telephone Number here under p...

Страница 48: ...and then slide it down into place Figure 3 8 Side View Completed Wall Mounting Bracket Using Wall Socket 2 Insert the two rubber bumpers into upper holes as shown in Figure 3 3 3 Connect the headset c...

Страница 49: ...4 6 Snap the legs located on the top of the bracket into the matching slots B at the top of the phone as shown in Figure 3 4 7 Lift and remove the handset hook tab rotate one half turn 180 degrees an...

Страница 50: ...Mount bracket may be used to elevate the FlexSet on a desktop in order to lower the viewing angle of the keyboard instead of being used to mount the phone on a wall Figure 3 9 Desktop Elevation Rubbe...

Страница 51: ...esk Elevation 3 Figure 3 10 Fitting the Desktop Elevation Bracket FlexSet 280x Figure 3 11 Fitting the Desktop Elevation Bracket FlexSet 120x Step 1 Insert Legs into Slots Step 2 Snap in Legs Step 1 I...

Страница 52: ...l Mount Desk Elevation 3 4 Snap the legs located on the thick edge of the bracket into the matching slots on the thick edge of the phone see Figure 3 12 Figure 3 12 Completed Desktop Elevation 28o Des...

Страница 53: ...B Assembling the Elevation Stand The Desk Elevation Stand may be used to elevate the FlexSet on a desktop at a sixty degree angle in order to lower the viewing angle of the keyboard Figure 3 13 FlexSe...

Страница 54: ...Place the stand s bottom legs into the matching narrow slots on the bottom of the phone See Figure 3 13 for details 6 Lift and remove the handset hook tab rotate one half turn 180 degrees and reinser...

Страница 55: ...Coral Terminal Equipment 3 13 Wall Mount Desk Elevation 3 Figure 3 15 Rear View Attach Cables to FlexSet with Desk Elevation Stand...

Страница 56: ...endicular to the desk 3 Push down firmly on the Desk Elevation stand at the point where the top legs join the slots The top legs release from the slots 4 Once the top legs are released gently pull the...

Страница 57: ...S It is used to supply external power to the FlexSet 280 281 and all other expansion modules FlexSet 40B etc It also supplies the power necessary for extended Coral FlexSet line lengths The PEX unit c...

Страница 58: ...e carrier s representative Once the module is fully assembled it is no longer necessary to keep the empty carton s Dispose of it in accord with local regulations Unpacking the Shipping Container The f...

Страница 59: ...the line cord from the RJ 11 LINE jack on the bottom of the FlexSet 280 281 3 Loosen and extract the screw securing the plastic base cover to the FlexSet 280 281 base and remove the plastic base cover...

Страница 60: ...ss the PEX module down until the connectors couple and the module rests comfortably on the base as shown in Figure 4 5 Figure 4 5 FlexSet 280 281 Base with PEX Installation 5 Insert and fasten the lar...

Страница 61: ...and Additional listen only Handset The PEX module adds an additional handset jack to the one located on the bottom of the FlexSet The additional jack is located at the bottom of the PEX module labeled...

Страница 62: ...4 6 Coral Terminal Equipment FlexSet PEX F PEX FS Installation 4 NOTES...

Страница 63: ...he compatibility as described in Table 5 1 In this document both units APA F and APDL FS are referred to as the APA Table 5 1 APA Compatibility 1 Overview Model Name APA PEX APA FS 7244 0168800 White...

Страница 64: ...e FlexSet 280S or FlexAPDL terminal is within the normal loop limit no external power is required to operate the APA s proprietary AP link An external power source is required if the FlexSet 280S stat...

Страница 65: ...pping Container The following items should be present in the box containing the APA kit FlexSet APA module One 1 13mm screw RS 232E cable with RJ 45 jack and 9 pin D type female connector Figure 5 2 F...

Страница 66: ...with Plastic Cover 2 Disconnect the line cord from the RJ 11 LINE jack on the bottom of the FlexSet 280S 3 Loosen and extract the screw securing the plastic base cover to the FlexSet base and remove...

Страница 67: ...ess the APA module down until the connectors couple and the module rests comfortably on the base as shown in Figure 5 5 Figure 5 5 FlexSet 280S FlexAPDL Base with APA Connected 5 Insert and fasten the...

Страница 68: ...rocess External Power Supply When the FlexSet 280S terminal is within the normal loop limit or the FlexSet 40B is not connected no external power is required to operate the APA s proprietary AP link I...

Страница 69: ...nications Equipment DCE device using a D type female connector The interface allows connection of a common asynchronous CTI products such as the CCM CAP FlexCT PathFinder etc Figure 5 7 shows use of t...

Страница 70: ...of the APA module Table 5 2 APA RS 232E Interface Pin Functions Pin Designation Pin Number Function RJ 45 Connector 9 Pin D Type Data Carrier Detector DCD 2 1 Receive Data RD 5 2 Output from APA Tran...

Страница 71: ...________________________________ Route DLIS Up to seven separate additional devices per keyset are available on FlexSet 280S with an APA The FlexSet 40B is one such device Additional devices attached...

Страница 72: ...ed system wide for all keysets as defined in Database Programming on page 1 9 The following parameter must be defined for all APA units in the system when a CAP or CCM application is running on a CSTS...

Страница 73: ...APA Table 6 1 PEX APA Compatibility The PEX APA Peripheral EXpansion Application Processor Adapter module is an optional module connected to the base of a FlexSet PEX APA F for FlexSet 280S PEX APA FS...

Страница 74: ...T CallMaster CCM Inspect for Damage 1 Inspect the shipping carton for evidence of physical damage or mishandling prior to opening 2 Inspect all parts for damage 3 Report any damage to the carrier imme...

Страница 75: ...PEX APA FS Installation 6 Figure 6 2 FlexSet PEX APA Module Power Supply 24 to 48 VDC RJ 11 jack telephone line to Coral system RJ 45 jack to PC RS 232 RJ 45 jack for optional FlexSet 40B Connection...

Страница 76: ...ase with Plastic Cover 2 Disconnect the line cord from the RJ 11 LINE jack on the bottom of the FlexSet 280 281 3 Loosen and extract the screw securing the plastic base cover to the FlexSet 280 281 ba...

Страница 77: ...the PEX APA module down until the connectors couple and the module rests comfortably on the base as shown in Figure 6 5 Figure 6 5 FlexSet 280 281 Base with PEX APA Connected 5 Insert and fasten the...

Страница 78: ...listen only Handset The PEX APA module adds an additional handset jack to the one located on the bottom of the FlexSet The additional jack located at the bottom of the PEX APA module labeled 2 and di...

Страница 79: ...Connections on page 5 7 Consult the Program Interface and Database Reference Manual for instructions on the database programming required when installing an APA Refer to Database Programming on page...

Страница 80: ...6 8 Coral Terminal Equipment FlexSet PEX APA F PEX APA FS Installation 6 NOTES...

Страница 81: ...1 and another FlexSet 40B or to two FlexSet 40Bs Up to three FlexSet 40Bs may be connected to a FlexSet 280 281 in standard operation thus the FlexSet 280 281 FlexSet 40B combination can support up to...

Страница 82: ...minal Equipment FlexSet 40B Installation 7 Figure 7 2 FlexSet 280S 281S With One FlexSet 40Bs Attached Figure 7 3 FlexSet 280S 281S With Three FlexSet 40Bs Attached 1st FlexSet 40B 2nd FlexSet 40B 3rd...

Страница 83: ...using the plastic connecting pieces for physical connection and and D BUS slots for electrical connection see Installation on page 7 7 The second keyset however is connected to the D BUS port of the...

Страница 84: ...a TPS power adapter located near the FlexSet 280 281 or through the FlexSet 280 281 line cord from a source at the main distribution frame 2 Pre Installation Requirements Model Name Base Adapter Requ...

Страница 85: ...e FlexSet 40B comes with a preprinted DESI label inserted beneath the faceplate Additional blank DESI Labels may be purchased from the dealer in Letter Cat No 7244 7400434 or A4 Cat No 7244 7400424 si...

Страница 86: ...f the FlexSet 40B and two are positioned towards the thinner end The thin hooks on the left and right sides of the connecting pieces Figure 7 7 fit into these and connect the two pieces The FlexSet 40...

Страница 87: ...side of the connector piece that is attached to the FlexSet 280 281 Insert the rear end first and then push the front end into position firmly until it clicks 4 Lift the front of the FlexSet 280 281...

Страница 88: ...cond FlexSet 40B to the free side of the first FlexSet 40B instead of the FlexSet 280 281 2 Set the 3 position slide switch located on the bottom lower side of the second FlexSet 40B to position 2 whe...

Страница 89: ...D BUS sockets as shown in Figure 7 9 2 Set the 3 position slide switch located on the bottom lower side of the third FlexSet 40B to the relevant position fourth FlexSet 40B 1 fifth FlexSet 40B 2 sixt...

Страница 90: ...EX APA ID Selection Switch Position 2 ID Selection Switch Position 2 3 2 1 3rd FlexSet 40B 3 2 1 1st FlexSet 40B 3rd RJ 45 Connector Cord 2nd RJ 45 Connector Cord 1st RJ 45 Connector Cord ID Selection...

Страница 91: ...ard end loses contact with the FlexSet 280 281 40B 4 Gently slide the plastic connecting piece away from the FlexSet 280 281 40B The connecting pieces are delicate do not use excessive force 5 Turn th...

Страница 92: ...Wall Mount Desk Elevation on page 3 1 2 The plastic connecting pieces are not necessary They can be removed if desired 3 Attach the FlexSet 280 281 and FlexSet 40B s to the Wall Mounts 4 Verify that...

Страница 93: ...ts can have a single FlexSet 40B attached 16 SFT SFTipx SFTsl SFT Office Cards Each port card can support up to 16 telephones and up to 16 FlexSet 40Bs The 16 FlexSet 40Bs can be distributed as needed...

Страница 94: ...xt page to change the default number Coral FlexiCom 400 5000 6000 Coral IPx 500 800 3000 4000 CDRS 200E The maximum number of FlexSet 40B or other expansion modules that can be added to the entire sys...

Страница 95: ...DPEMs provided by all GKT and DKT2xxx sets installed in the system in the KEYSETS_1 KEYSETS_3 parameters field If insufficient resources have been allocated in Sizes the following entry must be incre...

Страница 96: ...______ Route SIZ The maximum number of turret consoles allowed for the system is controlled by the following parameter TURRET CONSOLE Keyset Definition__________________________________________ Route...

Страница 97: ...External Power Required for 9 Required Always Not Required N A Not Applicable FlexSet 40B Extended line length see Table 1 1 APA RS 232 Port 2nd Handset Transient Surge Protection CPA N A 9 N A N A F...

Страница 98: ...s DC 15 Watts maximum There are two types of power supplies a TPS Telephone Power Supply for single unit supplies and b Central power supply for multiple unit supplies When to Use an External Power Su...

Страница 99: ...tion If using a single unit power supply 1 Plug the TPS power adapter into a 115 230 VAC receptacle 2 Insert the TPS plug into the jack marked DC on the rear of the FlexSet base Figure 8 1 115 230VAC...

Страница 100: ...to be supplied and their configuration as well as the type of power supply to be used and its output The power supply must provide 24 48 volts DC nominal 15 watts for each FlexSet When power is suppli...

Страница 101: ...t utilizes the same combination of Coral FlexSet 280S with APA F or Coral FlexSet 280 281 with PEX APA FS see page 6 1 but has no voice circuitry The FlexAPDL is not equipped with programmable buttons...

Страница 102: ...by the carrier s representative Once the terminal is fully assembled it is no longer necessary to keep the empty carton s Dispose of it in accord with local regulations Figure 9 1 FlexAPDL Terminal U...

Страница 103: ...e below using internal power supplied by the Coral station circuit Maximum Line Lengths depend on the gauge wire used to connect the Coral to the FlexAPDL A simple rule of thumb for any gauge wire is...

Страница 104: ...lexAPDL with APA External Connectors 2 Place the free end of the telephone line cord into the wall socket The connector will fit properly in one direction only If the connector does not fit into the s...

Страница 105: ...CE device using a D type female connector The interface allows connection of a common asynchronous CTI products such as the CCM CAP FlexCT PathFinder etc Figure 9 3 shows use of the pin number and fun...

Страница 106: ...le 9 3 FlexAPDL RS 232E Interface Pin Functions Pin Designation Pin Number Function RJ 45 Connector 9 Pin D Type Data Carrier Detector DCD 2 1 Receive Data RD 5 2 Output from FlexAPDL Transmit Data TR...

Страница 107: ...l number of FlexSets provided by all cards installed in the system If insufficient resources have been allocated in Sizes the entry must be increased or the keysets will not initialize KEYSETS_3 Set t...

Страница 108: ...e 1 9 one of the following protocol type parameters must be defined for APA PCC ACD_PC For PCC or CAP applications set the PCC parameter to YES Y the ACD_PC to NO N For ACD or Call Center applications...

Страница 109: ...used to set up all GKT FlexAPDL and FlexSet w APA units in the Coral system For more details see the Program Interface Reference Manual Chapter 9 Station Controls Parameters in parentheses are defaul...

Страница 110: ...9 10 Coral Terminal Equipment FlexAPDL Installation 9 NOTES...

Страница 111: ...inal The CPA has two audio output connection options see Figure 10 2 One is a 600 Ohm audio link option 1 while the other is a Hi Z connection option 2 for a high impedance link to a paging system In...

Страница 112: ...2 Coral Terminal Equipment CPA Installation 10 Figure 10 2 CPA Connections Amplifier 600 ohm option 1 Hi Z option 2 CPA Coral system Make announcement from any station Optional external power supply T...

Страница 113: ...y to keep the empty carton s Dispose of it in accordance with local regulations Figure 10 3 CPA Terminal Rear and Left View Unpacking the Shipping Container The following items should be present in th...

Страница 114: ...adapters are explained in External Power Supply on page 8 1 Maximum Line Lengths depend on the gauge wire used to connect the Coral to the CPA terminal When using the internal power supply supplied b...

Страница 115: ...w normally open or SPST NO contacts for activating external circuitry and devices The relay is designated to operate in conjunction with audio interface when the CPA is activated for external paging C...

Страница 116: ...manufacturer See the speaker manufacturer s literature for specific details The relay contact closes continuously during access to the voice page interface Although not always required the relay cont...

Страница 117: ...tive loads produce much lower arc levels than direct current DC operated loads If the contact must operate a DC powered inductive load the contact must be adequately protected by arc suppression devic...

Страница 118: ...he socket easily turn the connector over and retry The line is connected to the Coral through pins 3 and 4 on the RJ 11 line connector as shown in Figure 10 8 2 Place the free end of the telephone lin...

Страница 119: ...rnal voice paging amplifier through pins 3 and 4 on the RJ 11 voice connector as shown in Figure 10 8 Connecting via the Speaker Connection RCA Cord Hi Z 1 Place the RCA connector of the speaker coaxi...

Страница 120: ...should be connected instead of the CPA for volume changing Ring Setup The output ring at the audio jacks are preset by the default condition of the DKT station The CPA is not equipped with the abilit...

Страница 121: ...up to 8 keysets a 16 port card supports up to 16 keysets and a 24SFT card supports up to 24 keysets Verify that System Sizes allocates sufficient resources to accommodate the total number of FlexSets...

Страница 122: ...the port name may be entered for each CPA Up to five characters may be entered in the short field The short name is displayed on FlexSet 120x EKT VDK and DKT1110 station sets The full field may conta...

Страница 123: ...ve Power Limit 0 5A 120VAC 1 0A 30VDC External Paging 600 Ohm Connectors RJ 11 2 centered conductors 3 4 Termination Capacitor coupled transformer non grounded Impedance ON less than 600 Nom Impedance...

Страница 124: ...10 14 Coral Terminal Equipment CPA Installation 10 NOTES...

Страница 125: ...port FXS FXO Coral Voice over IP VoIP Installation Manual FlexIP SoftPhone FLIPS FlexIP SoftPhone FLIPS User Guide FlexSet IP 280S Coral FlexSet IP 280S Installation Manual FlexSet IP 280S User Guide...

Страница 126: ...11 2 Coral Terminal Equipment VoIP Terminals 11 NOTES...

Страница 127: ...er to the following documentation as required for information regarding the Coral VoIP terminals Table 12 1 Related Documentation for DKT DST DPEM Terminals Item Manual Installation instructions Digit...

Страница 128: ...12 2 Coral Terminal Equipment DKT DST DPEM Terminals Keyset Installation 12 NOTES...

Страница 129: ...e of the current manual Refer to the following documentation as required for information regarding the Coral VoIP terminals Table 13 1 Related Documentation for FlexAir CoralAIR Wireless Terminals Ite...

Страница 130: ...13 2 Coral Terminal Equipment FlexAir CoralAIR Wireless Handset Handset Installation 13 NOTES...

Страница 131: ......

Страница 132: ...S FlexAPDL and CPA TM International Headquarters Tadiran Telecom Ltd 18 Hasivim Street P O Box 7607 Petach Tikva 49170 Israel Tel 972 3 9262000 Fax 972 3 9262310 http www tadirantele com USA Headquart...

Отзывы: