The relay contacts provided on the CPA module have specific electrical limitations which are
described in detail in
. These limitations must not be exceeded. In
addition, the type of load the relay contact operates can have a great significance.
Ideally, the contact should operate a low voltage, low current, non-inductive load, such as solid
state device. When the voltage or current increases, or when an inductive load, such as a relay
coil or solenoid is connected, the likelihood of arcing across the contact increases. Contact
arcing occurs while the contact is opening, and burns away the precious metal surface,
increasing the chance of the contact being “welded” closed or failing completely. Arcing also
generates high frequency energy which may be coupled to any one of the data busses of the
Coral, causing unreliable or unpredictable system behavior.
If the contact is to operate a relay or solenoid, use an alternating current (AC) operated device,
and an AC power source, if at all possible. AC operated inductive loads produce much lower
arc levels than direct current (DC) operated loads.
If the contact must operate a DC powered inductive load, the contact must be adequately
protected by arc suppression devices.
illustrates the use of a common rectifier
diode as a simple arc suppression device. The diode is normally reverse biased (not conducting)
with the cathode (top side in the drawing) connected to the positive side of the power source.
Figure 10-7
DC Arc
Suppression for CPA Relay
When the inductive load is powered, a magnetic field is created around the coil windings.
When power is removed, the magnetic field quickly deteriorates, producing a reverse polarity
voltage (counter EMF) across the windings. This reverse polarity voltage is typically many
times the voltage which originally powered the coil, providing enough potential to arc across
the open relay contacts.
By placing the diode in the circuit, the reverse polarity current is conducted by the diode,
shunting the energy around the contacts. A rectifier rated at 1.0 ampere forward current (1.0A
I
F
), and a peak inverse (reverse) voltage of at least 250 volts (250V PIV, PRV, or V
RM
) should
be sufficient in most cases.
5
CPA Relay Special Considerations
Coral
system
CPA
2
(+)
(-)
5
Relay
Relay
DC
power
supply
Spike
suppression
diode
Содержание FlexSet 280
Страница 62: ...4 6 Coral Terminal Equipment FlexSet PEX F PEX FS Installation 4 NOTES...
Страница 80: ...6 8 Coral Terminal Equipment FlexSet PEX APA F PEX APA FS Installation 6 NOTES...
Страница 110: ...9 10 Coral Terminal Equipment FlexAPDL Installation 9 NOTES...
Страница 124: ...10 14 Coral Terminal Equipment CPA Installation 10 NOTES...
Страница 126: ...11 2 Coral Terminal Equipment VoIP Terminals 11 NOTES...
Страница 128: ...12 2 Coral Terminal Equipment DKT DST DPEM Terminals Keyset Installation 12 NOTES...
Страница 130: ...13 2 Coral Terminal Equipment FlexAir CoralAIR Wireless Handset Handset Installation 13 NOTES...
Страница 131: ......