A-96.250.211 / 171121
AMI Sodium P
Maintenance
69
Drawing
Assembling
1
Put new membranes on the membrane holders.
2
Place membrane 1 with holder in valve body.
3
Place washer 1 on membrane and push down carefully.
4
Place conical spring with smaller end on membrane holder.
5
Screw on the bottom screw fingertight.
6
Turn valve body upside down and place Teflon distance bar in
center hole of valve body.
7
Place membrane 2 with holder in valve body.
8
Place washer 2 on membrane and push down carefully.
9
Place long spring in solenoid.
10
Screw on the solenoid support fingertight.
Mounting
1
Mount the solenoid valve to the automatic regeneration module.
2
Mount the automatic regeneration module to the panel.
3
Connect tubes 3 and 4 (see
).
4
Connect the coil body [B] to the solenoid valve.
5
Screw on the knurled nut [A] fingertight.
A
B
C
D
E
F
G
H
I
K
L
M
N
O
Knurled nut
Coil body
Solenoid support
Washer 2
Long spring
Solenoid with membrane holder
Membrane 2
Valve body
Teflon distance bar
Membrane 1
Membrane holder
Conical spring
Washer 1
Bottom nut
A
B
C
D
E
F
G
H
I
K
L
M
N
O