A-96.250.211 / 171121
AMI Sodium P
Default Values
116
Parameter:
.................................................................... Sample Flow
Settings: Actuator: ............................................................ Frequency
Settings: Pulse Frequency:.....................................................120/min
Settings: Control Parameters: Setpoint:............................1000 B/s
Settings: Control Parameters: P-band: ...............................100 B/s
Common settings
Settings: Control Parameters: Reset time:..................................0 s
Settings: Control Parameters: Derivative Time: ..........................0 s
Settings: Control Parameters: Control Timeout:......................0 min
Settings: Actuator: ...................................................Time proportional
Cycle time: ...............................................................................60 s
Response time: ........................................................................10 s
Settings: Actuator ............................................................ Motor valve
Run time: ..................................................................................60 s
Neutral zone: ............................................................................. 5%
If Function = Timer:
Mode:.......................................................................................Interval
Interval: ...................................................................................1 min
Mode: .......................................................................................... daily
Start time:.......................................................................... 00.00.00
Mode:....................................................................................... weekly
Calendar; Start time: ......................................................... 00.00.00
Calendar; Monday to Sunday:.....................................................Off
Run time: ......................................................................................10 s
Delay: .............................................................................................5 s
Signal output:................................................................................cont
Output/Control: .............................................................................cont
Input
Active.............................................................................. when closed
Signal Outputs..............................................................................hold
Output/Control ................................................................................ off
Fault................................................................................................ no
Delay ............................................................................................10 s
Miscellaneous
Language:................................................................................English
Set default: ..................................................................................... no
Load firmware:................................................................................ no
Password:..............................................................for all modes 0000
Sample ID:..........................................................................- - - - - - - -
Line break detection ....................................................................... no