![Svantek SV 104BIS Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/svantek/sv-104bis/sv-104bis_user-manual_1409257057.webp)
57
SV
104BIS User Manual
The Inventory panel gives you more capabilities to manage the selected instrument, like: Refresh Catalogue,
Set Clock, Edit name, etc.; if you click right mouse button on the instrument’s row.
Figure 6-5
Inventory panel and its capabilities
The instrument’s name can be specified using the
Edit name
command.
In order to unlock additional options or measurement functions of the SV 104BIS instrument that are available
for purchase, use the
Manage options/functions
command in the instrument’s context menu. When you click
on this command, Supervisor downloads a list of available functionalities from the connected instrument and
displays it in the form of two lists: one for options and one for measurement functions.
Figure 6-6
Manage instrument options / functions dialog box
The
State
column, located at the right-
hand side of each option / function, contains the ‘Enabled’ label for
unlocked options / functions, and the ‘Unlock’ button for the ones that have not yet been unlocked. If you wish
to unlock an option or function that you purc
hased, press the ‘Unlock’ button and enter the unlocking code in
the window that appears.
Note:
If wrong code is entered three times since the instrument was last turned on, any later attempt to lock
or unlock an option will fail (regardless on whether the entered code is correct or not) until the instrument is
restarted.
Right-click
Содержание SV 104BIS
Страница 139: ...139 SV104BIS User Manual 250 Hz 315 Hz 400 Hz 500 Hz...
Страница 140: ...140 SV104BIS User Manual 630 Hz 800 Hz 1000 Hz 1250 Hz...
Страница 141: ...141 SV104BIS User Manual 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Страница 142: ...142 SV104BIS User Manual 2800 Hz 3150 Hz 3550 Hz 4000 Hz...
Страница 143: ...143 SV104BIS User Manual 4500 Hz 5000 Hz 5600 Hz 6300 Hz...
Страница 144: ...144 SV104BIS User Manual 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Страница 148: ...148 SV104BIS User Manual Figure C 4 Total directional characteristics asymmetrical axis...
Страница 150: ...150 SV104BIS User Manual 630 Hz 800 Hz 1000 Hz 1250 Hz...
Страница 151: ...151 SV104BIS User Manual 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Страница 152: ...152 SV104BIS User Manual 2800 Hz 3150 Hz 3550 Hz 4000 Hz...
Страница 153: ...153 SV104BIS User Manual 4500 Hz 5000 Hz 5600 Hz 6300 Hz...
Страница 154: ...154 SV104BIS User Manual 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Страница 161: ...161 SV104BIS User Manual 1 0 kHz 1 1 octave filter 500 Hz 1 1 octave filter 250 Hz 1 1 octave filter...
Страница 162: ...162 SV104BIS User Manual 125 Hz 1 1 octave filter 63 0 Hz 1 1 octave filter 31 5 Hz 1 1 octave filter...
Страница 166: ...166 SV104BIS User Manual 1 3 octave filters for 16 0 Hz 1 1 octave filter...
Страница 180: ...180 SV104BIS User Manual...