XLINK 500/100 Operations & Maintenance Manual page # 188
20.
Appendix A
–
Specifications
XLINK 100/500 - SPECIFICATIONS @ 25ºC and 12V input unless otherwise noted
Specifications subject to change without notice
GENERAL INFORMATION
Dimensions
XLink 500-1, XLink 100-1
NEMA-4
Inches: 4.5x6.2x1.6 (cm:11.4x15.8x4.1)
Inches:7.3x9.5x5.2 (cm:18.5x24.2x13.2)
Weight XLink500-1
1 lbs. (0.5 Kg)
IP rating
IP67 (NEMA variants)
Operating temperature
40° C to +70° C ( -40° F to +158° F)
Compliance
CE, FCC, ISED
POWER REQUIREMENTS
Input Voltage
9-20 Volts DC
10 -16 V for SDI-12 sensor support
Reverse power protected
Quiescent Power
Consumption
< 1 mA typical @ 12.5V
SDI-12 (Dedicated Interface)
Compliance
V1.3 data recorder
Power Supplied
500mA, short-circuit protected
ANALOG - SINGLE ENDED (XLink 500 only)
Number of inputs
2
Range*
0-5V
Accuracy @ 25°C
0.04% typ. FS
Resolution
0.3 µV
ANALOG - DIFFERENTIAL (XLink 500 only)
Number of Inputs
2
Range*
± 39mV, ± 312mV, ± 2.5V
Accuracy @ 25°C
0.04% typ. FS over 2.5V
Resolution
0.3 µV @ ± 2.5V scale
ANALOG - 4-20 mA (XLink 500 only)
Number of inputs
1
Range
0-22mA
Accuracy @ 25°C
0.14% FS
Load
Internal 200 Ohms
Digital Inputs/Outputs
Number of inputs
2