XLINK 500/100 Operations & Maintenance Manual page # 158
1.50. The next it was measured, M1 would read 1.50 (assuming the level does not change). The
Measurement Offset
would have changed from 0 to -2.00.
16.6.
Recording
To start the station, click the Start button in LinkComm, or type RECORDING = ON.
16.7.
Downloading the Log
The system will save the measured data in its flash memory each time a measurement is made.
The command LOG command will start a transfer of the log to the connected device.
Use NH to exclude the header; Use NE to omit events.
Help Log gives details on downloading the log.
>HELP LOG
DOWNLOAD or LOG will transfer the log from the unit
LOG ALL gets whole log, just LOG gets since last download,
LOG X gets X last days ("LOG 3" gets last 3 days worth of data)
LOG timeStart gets data since provided date
LOG timeStart timeEnd gets data between provided dates
time can be YYYY/MM/DD HH:MM:SS or YYYY/MM/DD or HH:MM:SS
eg. "LOG 12:00:00 13:00:00"
eg. "LOG 2006/01/20 12:00:00 2006/01/21 12:00:00"
append M1 to include only data from measurement one
eg. "LOG 3 M1 M2
append NH to omit log header, NE to omit events
append NY to download without YModem.