XLINK 500/100 Operations & Maintenance Manual page # 63
Press “Refresh Status”
to see latest data from each measurement
Right-click
and select “Refresh recent data” to update graphs.
6.6.
Examine Transmissions
Go to Dashboard
Select “Show Details”. Statistics on the
transmissions will be displayed
You may also see the telemetry statistics on the Telemetry tab, Telemetry Status
section.
6.7.
Examine Transmission Data
Go to Telemetry
Select “Show Tx Data”. The data from the last transmission is displayed along with data
that would be transmitted if one were made now. Details on the size and time required
to transmit are also displayed.
6.8.
Entering Manual Data
Go to Measurements
Select the desired measurement
Scroll to Processing, select “
Calibrate
”, and enter the desired value and press OK.
6.9.
Calibrating Sensors
Go to Measurements
Select the desired measurement
Scroll to Processing, select “Calibrate”, enter the desired sensor reading and press OK.
Whenever a sensor reading is calibrated, the system will log two readings
–
the value
before and the value after the calibration.
6.10.
Configuring SDI-12 Sensors
Go to Measurements
Select the desired measurement of an SDI-12 sensor
Scroll to Configuration and press “Send SDI
-
12 Command”. A menu will be provided
that allow you to select address, commands, and other SDI-12 details.
If the desired command is not in the Command drop-down list, simply enter it yourself
in the command box.
You may also access the SDI command menu from the Diagnostics tab.
6.11.
Downloading Log Data
Go to Data
Select desired “Span” and press “Download”.
When download is complete, press
“Save File…”. Note the file is named by the end time
in the span.