XLINK 500/100 Operations & Maintenance Manual page # 187
Enable Measurement setting
Use Script
Set Measurement setting
Script Function
to one of the provided script functions.
LinkComm will automatically list all compatible functions found in the script file.
Send setup to the unit
Press the Force button to verify that the measurement works as expected.
Setup a transmission that will use custom formatting:
Go to the telemetry tab
Setup the transmission
Enable Custom Script Format
Choose the appropriate
Script Format Function.
LinkComm will automatically list all
compatible functions found in the script file.
Send setup to the station.
Press the Show Tx Data button to verify that the formatting works as expected.
Setup script tasks:
Go to the script tab
Select S1 (or another script task) on the left side
Make the script
Active
Choose the appropriate
Script Function.
LinkComm will automatically list all
compatible functions found in the script file.
Choose when the script should run via the
Trigger
setting.
Send setup to the station
Press the Test Script button to verify the script does what it should.
Make sure the setup is in sync with the station and start recording
19.4.1.
Saving Scripts and Setups Together
Because setups and scripts work together, it makes sense to associate the setup file, and the
script file together.
When LinkComm’s Import Setup feature is used, if the chosen setup uses scripts, LinkComm will
prompt for the script file. When the Export Setup feature is used, both the setup and the script
are saved.
If the station setup is prepared, loading a script file into the station is easy:
Run LinkComm
Connect to the station
Choose Import Setup from the Menu
Choose the setup file
Choose the script file
Send setup