EVERGEN M SERIES USER MANUAL
ASSEMbLy
15
Sol by Sunna Design | 990 Biscayne Boulevard, Office 701, Miami, FL 33132, USA | 1.800.959.1329 | [email protected]
7
Coil remainder of fixture cable wire outside of the battery box and secure temporarily to solar panel mount
until product has been installed onto the pole.
CABLE
TIE
GROMMET
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
TITLE
B
1:24
-
EVERGEN MANUAL IMAGES
3 OF 3
82064-2
SHEET
SIZE
REVISION
SCALE
DRAWING NO
CAD REFERENCE
250 Bay Street
Victoria, BC Canada V9A 3K5
Tel [250] 380-0052
Fax [250] 380-0062
CHANGES SHALL BE INCORPORATED
ELECTRONICALLY BY THE DESIGN AUTHORITY
PDM MAINTAINED DATA
PROPRIETARY
COPYRIGHT © 2012 ALL RIGHTS RESERVED. NO
PART OF THIS
DOCUMENT MAY BE REPRODUCED
STORED IN A
RETRIEVAL SYSTEM, OR
TRANSMITTED IN ANY
FORM
ORIGINALLY DESIGNED BY
ORIGINALLY DRAWN BY
CHECKED BY
DATE
DATE
DATE
Ben Jolie
Ben Jolie
9/08/15
05/30/2017
UNLESS OTHERWISE SPECIFIED
DO NOT SCALE DRAWING
INTERPRET DIMENSIONS AND TOLERANCES
PER ASME Y14.100-2000
TOLERANCES APPLY AS SHOWN BELOW
DECIMALS SURF FINISH ANGLES
.X
.XX
.XXX
.XXXX
± .1
± .01
± .005
± .0005
63
1
INCHES
THIRD ANGLE PROJECTION
DOC #
DATE
21/12/11
57012
B
DOC REVISION
82064
ALL COMPONENTS AND PROCESSES TO BE ROHS COMPLIANT, CERTIFICATE REQUIRED WITH INITIAL SHIPMENT
FIXTURE CABLE
EMS CABLE
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
TITLE
B
1:16
A
EVERGEN MANUAL IMAGES
13 OF 13
82064
SHEET
SIZE
REVISION
SCALE
DRAWING NO
CAD REFERENCE
250 Bay Street
Victoria, BC Canada V9A 3K5
Tel [250] 380-0052
Fax [250] 380-0062
CHANGES SHALL BE INCORPORATED
ELECTRONICALLY BY THE DESIGN AUTHORITY
PDM MAINTAINED DATA
PROPRIETARY
COPYRIGHT © 2012 ALL RIGHTS RESERVED. NO
PART OF THIS
DOCUMENT MAY BE REPRODUCED
STORED IN A
RETRIEVAL SYSTEM, OR
TRANSMITTED IN ANY
FORM
ORIGINALLY DESIGNED BY
ORIGINALLY DRAWN BY
CHECKED BY
DATE
DATE
DATE
Ben Jolie
Ben Jolie
11/28/2016
05/27/2017
UNLESS OTHERWISE SPECIFIED
DO NOT SCALE DRAWING
INTERPRET DIMENSIONS AND TOLERANCES
PER ASME Y14.100-2000
TOLERANCES APPLY AS SHOWN BELOW
DECIMALS SURF FINISH ANGLES
.X
.XX
.XXX
.XXXX
± .1
± .01
± .005
± .0005
63
1
INCHES
THIRD ANGLE PROJECTION
DOC #
DATE
21/12/11
57012
B
DOC REVISION
82053
ALL COMPONENTS AND PROCESSES TO BE ROHS COMPLIANT, CERTIFICATE REQUIRED WITH INITIAL SHIPMENT
5
Connect fixture cable connector to EMS connector observing the keying feature. There will be an audible
"click" upon successful connection.
6
Where the cables enter the battery box, install a cable tie around all the cables on the inside of the box
and tighten.