EVERGEN M SERIES USER MANUAL
INSTALLATION
22
Sol by Sunna Design | 990 Biscayne Boulevard, Office 701, Miami, FL 33132, USA | 1.800.959.1329 | [email protected]
5
Tighten two (2) installed 3/8"-16 set screws in tenon adapter and torque to 17 ft-lbs (201 in-lbs.). Do not
exceed the specified torque to avoid stripping the threads in the tenon adapter
4
Make sure that the area between the solar panel(s) and direct sunlight is unobstructed.
THIS IS CRITICAL TO ENSURE PRODUCT PERFORMANCE AND TO MAINTAIN
BATTERY WARRANTY.
C
CAUTION
AUTION
2
Tighten installed 3/8"-16 set screws on integrated arm and torque to 17 ft-lbs (201 in-lbs.). Do not exceed
the specified torque to avoid stripping the threads in the tenon adapter.
SET
SCREWS
USE AS
DRILL
GUIDE
USE AS
DRILL
GUIDE
!GREASE!
SET
SCREWS
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
TITLE
B
1:24
-
EVERGEN MANUAL IMAGES
3 OF 4
82064-3
SHEET
SIZE
REVISION
SCALE
DRAWING NO
CAD REFERENCE
250 Bay Street
Victoria, BC Canada V9A 3K5
Tel [250] 380-0052
Fax [250] 380-0062
CHANGES SHALL BE INCORPORATED
ELECTRONICALLY BY THE DESIGN AUTHORITY
PDM MAINTAINED DATA
COPYRIGHT © 2012
ALL RIGHTS RESERVED. NO PART OF THIS
DOCUMENT MAY BE REPRODUCED STORED IN A
RETRIEVAL SYSTEM, OR TRANSMITTED IN ANY
FORM
PROPRIETARY
ORIGINALLY DESIGNED BY
ORIGINALLY DRAWN BY
CHECKED BY
DATE
DATE
DATE
Ben Jolie
Ben Jolie
02/03/2017
06/16/2017
UNLESS OTHERWISE SPECIFIED
DO NOT SCALE DRAWING
INTERPRET DIMENSIONS AND TOLERANCES
PER ASME Y14.100-2000
TOLERANCES APPLY AS SHOWN BELOW
DECIMALS SURF FINISH ANGLES
.X
.XX
.XXX
.XXXX
± .1
± .01
± .005
± .0005
63
1
INCHES
THIRD ANGLE PROJECTION
DOC #
DATE
21/12/11
57012
B
DOC REVISION
80871
ALL COMPONENTS AND PROCESSES TO BE ROHS COMPLIANT, CERTIFICATE REQUIRED WITH INITIAL SHIPMENT
SET
SCREWS
USE AS
DRILL
GUIDE
USE AS
DRILL
GUIDE
!GREASE!
SET
SCREWS
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
TITLE
B
1:24
-
EVERGEN MANUAL IMAGES
3 OF 4
82064-3
SHEET
SIZE
REVISION
SCALE
DRAWING NO
CAD REFERENCE
250 Bay Street
Victoria, BC Canada V9A 3K5
Tel [250] 380-0052
Fax [250] 380-0062
CHANGES SHALL BE INCORPORATED
ELECTRONICALLY BY THE DESIGN AUTHORITY
PDM MAINTAINED DATA
COPYRIGHT © 2012
ALL RIGHTS RESERVED. NO PART OF THIS
DOCUMENT MAY BE REPRODUCED STORED IN A
RETRIEVAL SYSTEM, OR TRANSMITTED IN ANY
FORM
PROPRIETARY
ORIGINALLY DESIGNED BY
ORIGINALLY DRAWN BY
CHECKED BY
DATE
DATE
DATE
Ben Jolie
Ben Jolie
02/03/2017
06/16/2017
UNLESS OTHERWISE SPECIFIED
DO NOT SCALE DRAWING
INTERPRET DIMENSIONS AND TOLERANCES
PER ASME Y14.100-2000
TOLERANCES APPLY AS SHOWN BELOW
DECIMALS SURF FINISH ANGLES
.X
.XX
.XXX
.XXXX
± .1
± .01
± .005
± .0005
63
1
INCHES
THIRD ANGLE PROJECTION
DOC #
DATE
21/12/11
57012
B
DOC REVISION
80871
ALL COMPONENTS AND PROCESSES TO BE ROHS COMPLIANT, CERTIFICATE REQUIRED WITH INITIAL SHIPMENT
3
Then orient solar panel(s) towards the equator (south in Northern Hemisphere).
7
Install supplied 1/4”-20 thru bolt with washers and nut then torque to 5 ft-lbs (64 in-lbs).
6
Drill two (2) 1/4” holes for tenon thru bolt from either side to ensure hole alignment, using the integrated
arm as a template.
USE CAUTION TO AVOID DRILLING INTO THE FIXTURE CABLE IF PRESENT.
N
NOTE
OTE
S