EVERGEN M SERIES USER MANUAL
INSTALLATION
29
Sol by Sunna Design | 990 Biscayne Boulevard, Office 701, Miami, FL 33132, USA | 1.800.959.1329 | [email protected]
7
8
9
Route fixture cable as shown and install Davit Arm accordingly.
Torque Davit Arm fasteners to manufacturers specifications.
Install and wire fixture as per the related section in this manual.
FIXTURE
CABLE
EMS
FIXTURE
CABLE
ROUTING
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
TITLE
B
1:64
-
EVERGEN MANUAL, DIRECT ARM
AND DAVIT ARM INSTALLATION
4 OF 5
82276
SHEET
SIZE
REVISION
SCALE
DRAWING NO
CAD REFERENCE
250 Bay Street
Victoria, BC Canada V9A 3K5
Tel [250] 380-0052
Fax [250] 380-0062
CHANGES SHALL BE INCORPORATED
ELECTRONICALLY BY THE DESIGN AUTHORITY
PDM MAINTAINED DATA
PROPRIETARY
COPYRIGHT © 2012 ALL RIGHTS RESERVED. NO
PART OF THIS
DOCUMENT MAY BE REPRODUCED
STORED IN A
RETRIEVAL SYSTEM, OR
TRANSMITTED IN ANY
FORM
ORIGINALLY DESIGNED BY
ORIGINALLY DRAWN BY
CHECKED BY
DATE
DATE
DATE
Ben Jolie
Ben Jolie
02/03/2017
08/09/2017
UNLESS OTHERWISE SPECIFIED
DO NOT SCALE DRAWING
INTERPRET DIMENSIONS AND TOLERANCES
PER ASME Y14.100-2000
TOLERANCES APPLY AS SHOWN BELOW
DECIMALS SURF FINISH ANGLES
.X
.XX
.XXX
.XXXX
± .1
± .01
± .005
± .0005
63
1
INCHES
THIRD ANGLE PROJECTION
DOC #
DATE
21/12/11
57012
B
DOC REVISION
80871
ALL COMPONENTS AND PROCESSES TO BE ROHS COMPLIANT, CERTIFICATE REQUIRED WITH INITIAL SHIPMENT
FIXTURE
CABLE
EMS
FIXTURE
CABLE
ROUTING
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
TITLE
B
1:64
-
EVERGEN MANUAL, DIRECT ARM
AND DAVIT ARM INSTALLATION
4 OF 5
82276
SHEET
SIZE
REVISION
SCALE
DRAWING NO
CAD REFERENCE
250 Bay Street
Victoria, BC Canada V9A 3K5
Tel [250] 380-0052
Fax [250] 380-0062
CHANGES SHALL BE INCORPORATED
ELECTRONICALLY BY THE DESIGN AUTHORITY
PDM MAINTAINED DATA
PROPRIETARY
COPYRIGHT © 2012 ALL RIGHTS RESERVED. NO
PART OF THIS
DOCUMENT MAY BE REPRODUCED
STORED IN A
RETRIEVAL SYSTEM, OR
TRANSMITTED IN ANY
FORM
ORIGINALLY DESIGNED BY
ORIGINALLY DRAWN BY
CHECKED BY
DATE
DATE
DATE
Ben Jolie
Ben Jolie
02/03/2017
08/09/2017
UNLESS OTHERWISE SPECIFIED
DO NOT SCALE DRAWING
INTERPRET DIMENSIONS AND TOLERANCES
PER ASME Y14.100-2000
TOLERANCES APPLY AS SHOWN BELOW
DECIMALS SURF FINISH ANGLES
.X
.XX
.XXX
.XXXX
± .1
± .01
± .005
± .0005
63
1
INCHES
THIRD ANGLE PROJECTION
DOC #
DATE
21/12/11
57012
B
DOC REVISION
80871
ALL COMPONENTS AND PROCESSES TO BE ROHS COMPLIANT, CERTIFICATE REQUIRED WITH INITIAL SHIPMENT
X
RISE OF ARM
130.2mm
5.125in
228.6mm
9.0in
17.5mm
.69in
THRU
25.4mm
1.00in
FIXTURE
SIDE ONLY
17.5mm
.69in
THRU
X
RISE OF ARM
FIXTURE
CABLE
HOLE
FIXTURE
HEIGHT
!
NOTES
1
TYPE YOUR NOTES IN HERE
2
FEEL FREE TO MOVE/RESIZE THIS TABLE
REV ECO #
DESCRIPTION
DATE
DRAWN BY
MATERIAL SEE PART MATERIAL
FINISH
N/A
FINISH
SPEC
N/A
COLOR
N/A
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
TITLE
B
1:64
-
EVERGEN MANUAL, DIRECT ARM
AND DAVIT ARM INSTALLATION
3 OF 5
82276
SHEET
SIZE
REVISION
SCALE
DRAWING NO
CAD REFERENCE
250 Bay Street
Victoria, BC Canada V9A 3K5
Tel [250] 380-0052
Fax [250] 380-0062
CHANGES SHALL BE INCORPORATED
ELECTRONICALLY BY THE DESIGN AUTHORITY
PDM MAINTAINED DATA
PROPRIETARY
COPYRIGHT © 2012 ALL RIGHTS RESERVED. NO
PART OF THIS
DOCUMENT MAY BE REPRODUCED
STORED IN A
RETRIEVAL SYSTEM, OR
TRANSMITTED IN ANY
FORM
ORIGINALLY DESIGNED BY
ORIGINALLY DRAWN BY
CHECKED BY
DATE
DATE
DATE
Ben Jolie
Ben Jolie
02/03/2017
08/09/2017
UNLESS OTHERWISE SPECIFIED
DO NOT SCALE DRAWING
INTERPRET DIMENSIONS AND TOLERANCES
PER ASME Y14.100-2000
TOLERANCES APPLY AS SHOWN BELOW
DECIMALS SURF FINISH ANGLES
.X
.XX
.XXX
.XXXX
± .1
± .01
± .005
± .0005
63
1
INCHES
THIRD ANGLE PROJECTION
DOC #
DATE
21/12/11
57012
B
DOC REVISION
80871
ALL COMPONENTS AND PROCESSES TO BE ROHS COMPLIANT, CERTIFICATE REQUIRED WITH INITIAL SHIPMENT
5
6
Drill the fixture cable hole through the side of the pole that the arm will mount to as shown.
Be sure to break all sharp edges that will come into contact with the harness wiring.