EVERGEN M SERIES USER MANUAL
INSTALLATION
32
Sol by Sunna Design | 990 Biscayne Boulevard, Office 701, Miami, FL 33132, USA | 1.800.959.1329 | [email protected]
Wiring Diagram
_
+
+
_
GROUND
+
_
FUSE
(+) POSITIVE (RED)
(-) NEGATIVE (BLACK)
GROUND (GREEN)
LIGHT FIXTURE
+
_
+
_
+
_
SOLAR
PANEL
LIGHT
FIXTURE
EMS
BATTERY
BOX
_
+
EMS
SOLAR PANEL
12V PARALLEL BATTERY CONFIGURATION
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
TITLE
B
1:4
A
EVERGEN EMS QUICK START
GUIDE IMAGES
3 OF 4
XXXXX
SHEET
SIZE
REVISION
SCALE
DRAWING NO
CAD REFERENCE
250 Bay Street
Victoria, BC Canada V9A 3K5
Tel [250] 380-0052
Fax [250] 380-0062
CHANGES SHALL BE INCORPORATED
ELECTRONICALLY BY THE DESIGN AUTHORITY
PDM MAINTAINED DATA
COPYRIGHT © 2012
ALL RIGHTS RESERVED. NO PART OF THIS
DOCUMENT MAY BE REPRODUCED STORED IN A
RETRIEVAL SYSTEM, OR TRANSMITTED IN ANY
FORM
PROPRIETARY
ORIGINALLY DESIGNED BY
ORIGINALLY DRAWN BY
CHECKED BY
DATE
DATE
DATE
Ben Jolie
Ben Jolie
12/02/2014
03/21/2017
UNLESS OTHERWISE SPECIFIED
DO NOT SCALE DRAWING
INTERPRET DIMENSIONS AND TOLERANCES
PER ASME Y14.100-2000
TOLERANCES APPLY AS SHOWN BELOW
DECIMALS SURF FINISH ANGLES
.X
.XX
.XXX
.XXXX
± .1
± .01
± .005
± .0005
63
1
INCHES
THIRD ANGLE PROJECTION
DOC #
DATE
21/12/11
57012
B
DOC REVISION
81264
ALL COMPONENTS AND PROCESSES TO BE ROHS COMPLIANT, CERTIFICATE REQUIRED WITH INITIAL SHIPMENT
+
+
+
_
GROUND
+
_
FUSE
(+) POSITIVE (RED)
(-) NEGATIVE (BLACK)
GROUND (GREEN)
LIGHT FIXTURE
+
_
+
_
+
_
SOLAR
PANEL
LIGHT
FIXTURE
EMS
BATTERY
BOX
_
_
_
+
EMS
SOLAR PANELS
12V PARALLEL BATTERY CONFIGURATION
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
TITLE
B
1:4
A
EVERGEN EMS QUICK START
GUIDE IMAGES
4 OF 4
XXXXX
SHEET
SIZE
REVISION
SCALE
DRAWING NO
CAD REFERENCE
250 Bay Street
Victoria, BC Canada V9A 3K5
Tel [250] 380-0052
Fax [250] 380-0062
CHANGES SHALL BE INCORPORATED
ELECTRONICALLY BY THE DESIGN AUTHORITY
PDM MAINTAINED DATA
COPYRIGHT © 2012
ALL RIGHTS RESERVED. NO PART OF THIS
DOCUMENT MAY BE REPRODUCED STORED IN A
RETRIEVAL SYSTEM, OR TRANSMITTED IN ANY
FORM
PROPRIETARY
ORIGINALLY DESIGNED BY
ORIGINALLY DRAWN BY
CHECKED BY
DATE
DATE
DATE
Ben Jolie
Ben Jolie
12/02/2014
03/21/2017
UNLESS OTHERWISE SPECIFIED
DO NOT SCALE DRAWING
INTERPRET DIMENSIONS AND TOLERANCES
PER ASME Y14.100-2000
TOLERANCES APPLY AS SHOWN BELOW
DECIMALS SURF FINISH ANGLES
.X
.XX
.XXX
.XXXX
± .1
± .01
± .005
± .0005
63
1
INCHES
THIRD ANGLE PROJECTION
DOC #
DATE
21/12/11
57012
B
DOC REVISION
81264
ALL COMPONENTS AND PROCESSES TO BE ROHS COMPLIANT, CERTIFICATE REQUIRED WITH INITIAL SHIPMENT
One Panel System
Two Panel System