CI380X01R5

INSTALLATION INSTRUCTIONS

INSTRUCTIONS D’INSTALLATION

TO INSTALL:

TENON MOUNT

NOTE:

 Tenon must be 3.75" or taller.

STEP 1:

To adjust the angle of the luminaire, 

reference the Angle Adjustment Section.

STEP 2:

Remove (3) 8-32 Phillips head screws that 
secure the Mounting Clamp Cover to the 
mounting clamp and set aside. See 

Figure 1.

STEP 3: 

Remove the mounting clamp cover exposing 
the wire connections and set aside.  See 

Figure 1.

STEP 4:

Remove the terminal block bracket by 
removing the (1) 8-32 Phillips head screw and 
set aside. See 

Figure 1.

STEP 5: 

Route the supply wire up the vertical tenon 
and through the center hole of the adjustable 
slip fitter. Secure the supply wire to keep from 
sliding back down the pole. See 

Figure 2.

STEP 6: 

Make electrical connections per 

Electrical 

Connection

 section.

STEP 7:

Replace terminal block bracket into wiring 
compartment removed in Step 4.

STEP 8: 

Replace cover and cover gasket using the (3) 
8-32 pan head screws remove in Step 2.

 

STEP 9: 

Fit the Adjustable Slip Fitter over the vertical 
tenon making sure the fitter is centered on the 
tenon.

STEP 10:

Using 3/16" Allen wrench, hand tighten set 
screws in a crossing pattern around tenon 
until tip of screws engage tenon. (Do not fully 
tighten). Torque set screws to 40 in. lbs. (4.5 
N-m) See Cross Pattern Tightening Chart. 

STEP 11: 

Repeat torque set screws to 80 in. lbs. (9.0 
N-m) following Cross Pattern chart. 

STEP 12: 

Repeat torque set screws to 120-130 in. lbs. 
(13.5-14.5 N-m) following Cross Pattern chart. 

DO NOT

 over-tighten.

*

*

*

*

*

Bottom row of set-screws

1

Mounting

Clamp Cover

Terminal

Block Bracket

Mounting

Clamp

Adjustable 

Slip Fitter

Tenon

2

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be followed 

including the following:

READ AND FOLLOW ALL SAFETY 

INSTRUCTIONS

1.  DANGER

- Risk of shock- Disconnect power before installation.

DANGER

 – Risque de choc – Couper l’alimentation avant l’installation.

2.  This luminaire must be installed in accordance with the NEC or your local electrical 

code. If you are not familiar with these codes and requirements, consult a qualified 

electrician. 

Ce produit doit être installé conformément à NEC ou votre code électrique local. 

Si vous n’êtes pas familier avec ces codes et ces exigences, veuillez contacter un 

électricien qualifié.

3.  If NEMA

® 

 Photo Control is installed refer to NEMA

® 

 Receptacle Section for 

instructions.

4.  Ensure the mounting surface is capable of supporting the weight of the luminaire 

after installation.

Veiller à la surface de montage est capable de supporter le poids du luminaire 

après l’installation

5.  Due to the weight of the luminaire, 2 people may be necessary during installation.

6.  WARNING: This luminaire is intended to be mounted to a vertical tenon only.

SAVE THESE INSTRUCTIONS FOR 

FUTURE REFERENCE

•  Prior to installation, store luminaire in a dry location 

protected from rain, dust, and outdoor environment.  
If equipped with a photocell receptacle, do not store 
or install luminaire outdoors without immediately 
installing a suitable photocell, shorting cap, or 
other compatible device. Do NOT leave receptacle 
open to environmental elements.  Luminaires with 
a top-mounted photocell receptacle should not be 
installed in an up-light position or at a tilt greater 
than 45 degrees from the down-light position.