FIELD ADJUSTABLE DIMMING - OPTIONAL

STEP 1: 

This luminaire may be provided with field adjustable dimming. 
Luminaires leave the factory adjusted to the maximum setting 
which is Position 9 as shown in 

Figure 5.

STEP 2: 

Locate the luminaires electrical label and verify the luminaires LED 
count and the maximum current available.

STEP 3: 

The Dimming module is located inside the Mounting Clamp 
on the Terminal Block Bracket. Remove (3) 8-32 Phillips 
head screws that secure the Mounting Clamp Cover to the 
Mounting Clamp and set aside. See 

Figure 1

 

on page 1.

STEP 4: 

Remove the mounting clamp cover exposing the wire connections 
and set aside.  See 

Figure 1

 

on page 1.

STEP 5:

Remove the terminal block bracket by removing the (1) 8-32 Phillips 
head screw and set aside. See 

Figure 1 

on page 1.

STEP 6:

Establish the desired input power multiplier by referring to the 
product dimming spec sheet and turn the switch to the correlating 
position.

STEP 7: 

Adjust the Dimming Module to the selected position, replace the 
terminal block bracket and the Mounting Clamp Cover ensuring no 
wires are pinched and reinstall the screws that were removed in 
Step 3.

5

ELECTRICAL CONNECTIONS

STEP 1:

Make the following Electrical Connections to supply cord:

a.  For 120/277/347V connect the black fixture lead to the 

voltage supply position of the terminal block or Hot 1 (for 
208/240/480V wiring).

b.  For 120/277/347V connect the white fixture lead to the 

neutral supply position of the terminal block or Hot 2 (for 

208/240/480V wiring).

c.  Connect the green or green/yellow ground lead to the 

green wire position of the terminal block.

d.  If Dimming is an option; connect the violet dimming 

positive lead to the supply dimming positive lead.

e.  If Dimming is an option; connect the grey dimming 

negative lead 

to the supply dimming negative lead

   LINE
OR HOT 1

GREEN

LINE-BLACK

GROUND-GREEN

NEUTRAL-WHITE

DIM (-) GREY

DIM (+) VIOLET

NEUTRAL

OR HOT 2

VIOLET

GREY

SUPPL

Y WIRING

(DIMMING OPTIONAL)

LUMINAIRE

TERMINAL

BLOCK