MR3 & MR6 Luminaires are suitable for use in the following areas  as defined by the National 

Electrical Code (NEC) and the Canadian Electrical Code (CEC):

Certified to:   

 

UL 1598, UL 1598A and UL 8750

 

 

 

 

CSA C22.2 NO. 250.0 and CSA C22.2 NO 250.13;

        

MR3 & MR6 luminaires are designed for use indoors, outdoors, wet locations, and areas containing 

moisture, dirt, corrosion, vibration, and rough usage. The MR luminaire is also certified for use as a 

marine, outside type (saltwater) non-recessed luminaire. 

Housing:  

 

 

Copper-free Cast Aluminium with Polycarbonate lens

Voltage: 

 

 

AC: 120-277 VAC  |  HV: 347:  347 VAC  50/60Hz

Rated Current: 

 

MR3: 0.25A@120 VAC |  0.10A@347 VAC  

 

 

 

 

MR6: 0.50A@120 VAC |  0.20A@347 VAC

Connections:   

 

3/4” NPT Conduit  |  Black: Line  |  White: Neutral  |  Green: Ground

 

 

 

 

All field wiring supply conductors shall be rated 90°C minimum and rated for 

 

 

 

 

supply voltage (300V AC Models, 600V HV models). Class 1 Wiring Only.

Temperature Range:   

-40° C to +55° C

Ingress Protection:   

IP66 and IP67 rated for surface/suspension mount, yoke mount, pendant hook, 

 

 

 

 

and conduit connected installations only.  |  Suitable For Wet Locations. Marine 

    Outside 

Type 

(Salt 

Water).

APPLICATION

TM

Nemalux

I N D U S T R I A L

MR-GEN

rev. A-15

1-4

www.nemalux.com  |   [email protected]  |   Tel 403•242•7475  |   Fax 403•243•6190 

MADE IN CANADA

INSTALLATION INSTRUCTIONS

E477827

E477827

Содержание MR-GEN

Страница 1: ...age AC 120 277 VAC HV 347 347 VAC 50 60Hz Rated Current MR3 0 25A 120 VAC 0 10A 347 VAC MR6 0 50A 120 VAC 0 20A 347 VAC Connections 3 4 NPT Conduit Black Line White Neutral Green Ground All field wiri...

Страница 2: ...CONFIGURATION SUSPENSION MOUNTING CONFIGURATION TM Nemalux I N D U S T R I A L MR GEN rev A 15 2 4 www nemalux com sales nemalux com Tel 403 242 7475 Fax 403 243 6190 MADE IN CANADA INSTALLATION INST...

Страница 3: ...ug two provided OR Install Direct Rigid Conduit as per local electrical code For direct rigid conduit installation torque hand tight plus 2 to 3 turns NOTE To aid in assembly and protection against in...

Страница 4: ...g connectors provided Connect output wiring using the same wiring connectors Feed output wiring through the remaining NPT hub as described in Step 5 above For dimming connect 18AWG or larger conductor...

Страница 5: ...tallation instructions provided with fixture STEP 4 Set Screw TM Nemalux I N D U S T R I A L MR GEN rev A 15 1 1 www nemalux com sales nemalux com Tel 403 242 7475 Fax 403 243 6190 MADE IN CANADA MR P...

Страница 6: ...7 N m 62 in lbs STEP 5 Install Back Cover Plate with 4x M4 Flat head screws and adhesive backed gasket Apply gasket with adhesive side applied to mount main body Torque to 2 N m 17 in lbs MR WM WALL M...

Страница 7: ...al electrical codes for the specific hazardous locations Torque cable gland base and dome nut to manufacturer s recommended specification OR Install Direct Rigid Conduit as per local electrical code F...

Страница 8: ...position Torque hardware nuts to 9 N m 80 in lbs STEP 6 Resume installation instructions provided with fixture STEP 4 43mm 4 x 7mm 72mm 2 83in 51mm 60 deg MR YM YOKE MOUNT INSTALLATION Ordered Separat...

Страница 9: ...ng in MR high vibration yoke mount and install MR luminaire into yoke The raised circular bosses on the MR cheek plates should register inside of the large circular holes on the MR high vibration yoke...

Страница 10: ...ead lubricant sealant is necessary Un used conduit opening must be plugged to maintain the integrity of the enclosure STEP 3 Install Secondary Safety Cable by looping appropriate steel cable or chain...

Страница 11: ...TEP 3 Slide anti rotation lock onto suspension hook assembly and install hook assembly into NPT threaded entry Tighten to hand tight plus 1 to 2 turns Slide anti rotation lock into place and tighten s...

Страница 12: ...in to fixed eye bolt not supplied using the second stainless steel oval shaped thread ed connecting link Alternate attachment method Wrap loose end of chain around fixed beam or other immovable suppor...

Отзывы: