112
Netra ct Server Installation Guide • September 2002
FIGURE 6-53
Connecting the DC Input Power Cable to the DC Connectors
3. Turn on the circuit breakers to provide power to the servers.
If you want to disconnect the DC input power cable from the DC connector at some
point in the future, turn the circuit breakers off, then squeeze the two tabs on the
sides of the DC input power cable and gently disconnect the DC input power cable
from the DC power supply.
Caution –
Do not attempt to disconnect the DC input power cable from the DC
connector until you have turned off the power from the DC power source through
the circuit breakers.
Содержание Netra ct
Страница 18: ...xviii Netra ct Server Installation Guide September 2002...
Страница 20: ...2 Netra ct Server Installation Guide September 2002...
Страница 36: ...18 Netra ct Server Installation Guide September 2002...
Страница 58: ...40 Netra ct Server Installation Guide September 2002...
Страница 168: ...A 150 Netra ct Server Installation Guide September 2002...