Chapter 6
Cabling the System
87
▼
To Connect Cables to the CompactPCI Front-
Access I/O Cards
1. Locate the I/O card.
FIGURE 5-2
on page 44 shows the possible locations for the I/O cards in the Netra ct
800 server and
FIGURE 5-4
on page 46 shows the possible locations for the I/O cards
in the Netra ct 400 server.
2. Make the necessary cable connections to the CompactPCI I/O cards.
Tighten the screws on the cable to a torque of 0.23 N.m (2 in.-lb).
Refer to the documentation that you received with the CompactPCI I/O cards for
more information.
Cabling for the Rear-Access Model
■
“To Connect Cables to the CPU Rear Transition Card” on page 87
■
“To Connect Cables to the Alarm Rear Transition Card (Rear-Access Models
Only)” on page 97
■
“To Connect Cables to the Rear-Access I/O Cards” on page 103
▼
To Connect Cables to the CPU Rear Transition
Card
1. Go to the rear of the chassis and locate the CPU rear transition card.
FIGURE 6-29
shows the location of the CPU rear transition card in the Netra ct 800
server, and
FIGURE 6-30
shows the location of the CPU rear transition card in the
Netra ct 400 server.