Auto-diagnosis Engine (ADE) Case Study

Sun Confidential: Internal Only

 

 

125

SunService  Sun Microsystems, Inc. All Rights Reserved. Enterprise Services

Содержание Fire F3800

Страница 1: ...Sun Microsystems Ltd Citygate Cross Street Sale Manchester M33 7JF UK Sun Confidential Internal Only Brian Jackson July 2005 Sun Fire 3800 6800 Quick Reference Guide...

Страница 2: ...is a registered trademark in the U S and other countries exclusively licensed through X Open Company Ltd The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems Inc for its us...

Страница 3: ...s pays Les produits portant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc UNIX est une marques d pos e aux Etats Unis et dans d autres pays et licenci e exclusi...

Страница 4: ...Sun Confidential Internal Only Please Recycle...

Страница 5: ...Board ASICs 22 PCI I O Physical 23 cPCI I O Physical 24 I O Board Summary 24 Sun Fireplane Switch Boards 25 How it all bolts together 26 System Controller Boards 27 Nvram nvci SC flashproms 28 System...

Страница 6: ...tp server for the System Controllers 56 setupplatform 57 Rebooting the system controller 58 Setting up the loghost 59 Edit syslog conf on the admin workstation 59 syslog Parsing Tools 59 Powering On a...

Страница 7: ...used console busy 100 Navigating Between Shells 101 Escape sequence 102 showescape 102 setescape 102 Sun Fire Device Tree 103 Sun Fire Physical Device Mapping 105 Node Mapping 105 System Board Mapping...

Страница 8: ...Sun Confidential Internal Only Sun Fire 3800 6800 Quick Reference Guide SunService Sun Microsystems Inc All Rights Reserved Enterprise Services...

Страница 9: ...n and Service Manual 806 4211 xx Refer to the Platform Administration Manual and System Controller Commands Reference Manual specific to the firmware you are using For an exhaustive list of all Sun Fi...

Страница 10: ...have been developed under the codename of serengeti They have gone through a number of name changes since their inception they are included below for your reference K6 Serengeti SP Serengeti 8 Sun Fir...

Страница 11: ...Fire 3800 has the following features Support for 2 to 8 UltraSPARC III III Cu processors mounted on two system boards Up to 64 Gbytes of error checking and correction ECC memory Twelve hot swappable c...

Страница 12: ...The Sun Fire 4800 has the following features Support for 2 to 12 UltraSPARC III III Cu processors mounted on three system boards Up to 96 Gbytes of ECC memory Sixteen PCI I O slots mounted on two I O...

Страница 13: ...rucks ships and so on The Sun Fire 4810 has the following features Support for 2 to 12 UltraSPARC III III Cu processors mounted on three system boards Up to 96 Gbytes of ECC memory Sixteen PCI I O slo...

Страница 14: ...tes of ECC memory Thirty two PCI I O slots or 16 hot swappable cPCI slots or combinations of PCI and cPCI mounted on four I O boards Support for up to four domains Three or four domains require two se...

Страница 15: ...ects of the platform Refer to the Sun Fire Systems Site Planning Guide part number 805 7365 xx Dimensions clearance requirements weight Power requirements BTUs hr cooling requirements Power factor Con...

Страница 16: ...d the L1 Sun Fireplane switch The system board L1 level 1 Sun Fireplane switching logic consists of an address repeater AR and 4 x data switch DX ASICs Each system board contains a system data control...

Страница 17: ...f memory Each memory bank consists of four dual inline memory modules DIMMs which gives 8 x DIMMS per CPU See page 18 Memory capacity can also be mixed but not within the same bank The processor s L2...

Страница 18: ...e any DIMMs installed in its corresponding DIMM bank but a populated DIMM bank must have a corresponding CPU processor installed in order for that memory to be utilised The system board supports the f...

Страница 19: ...enabled pass 2048M DRAM N0 SB2 P1 B0 L2 enabled pass 2048M DRAM N0 SB2 P1 B1 L1 enabled pass 2048M DRAM N0 SB2 P1 B1 L3 enabled pass 2048M DRAM N0 SB2 P2 B0 L0 enabled pass 2048M DRAM N0 SB2 P2 B0 L2...

Страница 20: ...1 1 3 J14500 1 0 2 J14501 CPU B 1 1 2 CPU P1 J14400 1 0 1 J14401 1 1 1 J14300 1 0 0 J14301 1 1 0 J13600 0 0 3 J13601 0 1 3 J13500 0 0 2 J13501 CPU A 0 1 2 CPU P0 J13400 0 0 1 J13401 0 1 1 J13300 0 0 0...

Страница 21: ...ut is clearly marked on the cabinets However remember that in the F6800 the System boards are numbered non sequentially from left to right SB0 SB2 SB4 SB1 SB3 SB5 platform Number of System Boards Slot...

Страница 22: ...ard PCI logic supporting three 33 MHz 64 bit 5VDC cards Each PCI I O board contains a system data controller SDC Again the SDC multiplexes the console bus connections and acts as the brains behind the...

Страница 23: ...810 platforms support an 8 slot PCI board illustrated below and a 4 slot cPCI I O board Note There are 6 slots which run at 33MHz and 2 slots which run at 33 66 MHz balanced across two schizo ASICs Ba...

Страница 24: ...cPCI I O Physical Below is an illustration of the 6 slot cPCI board is used in the F3800 The F3800 only supports a 6 slot cPCI board The 4 slot cPCI board is very similar to the layout below I O Boar...

Страница 25: ...ey are alternatively known as level 2 L2 switches and repeaters although the preferred name is the Sun Fireplane switch In the F3800 the equivalent of two Sun Fireplane switch board is integrated into...

Страница 26: ...e second level switches are incorporated in the centerplane Transactions originating from the first level switches on the system and I O boards are sent to the second level switches The second level s...

Страница 27: ...onnects the system controller to the console bus which in turn is connected to the system boards I O boards and Sun Fireplane switch boards Each system board I O board and Sun Fireplane switch board c...

Страница 28: ...application called the ScApp which is held in an 8 MB flashPROM on board This is the sgsgsc flash file in the flashupdate patch The SC maintains a centralized TOD hostids and MAC addresses and its ow...

Страница 29: ...ou have both SCs present during the boot sequence of the SSC you will get a messages indicating that clock failover is enabled Jun 06 10 32 23 4800a sc0 Platform SC Clock failover enabled If one of th...

Страница 30: ...as scname sc Improved diagnostics recovery Firmware compatibility New Commands setfailover showfailover Modified Commands password setupplatform setupdomain showboards showdomain showplatform showrese...

Страница 31: ...t a lower up front cost and the remainder of the CPU memory board cost is not paid until the resources are used by ordering COD right to use RTU licenses New Commands addcodlicense deletecodlicense sh...

Страница 32: ...f the parameter hang policy is set to reset using the setupdomain command the SC automatically initiates an XIR and re boots the hung domain Dynamic Domain hostID MAC Address assignment Useful for run...

Страница 33: ...ct data between host and client and also uses authentication mechanisms to identify hosts and clients The SC supports five SSH connections along with the serial port connection New Commands setescape...

Страница 34: ...C V2s by running showsc v4u 6800a sc0 SC showsc SC SSC0 Main System Controller V2 SC Failover disabled Clock failover enabled SC date Tue Aug 10 16 06 27 BST 2004 SC uptime 6 days 7 hours 41 minutes 2...

Страница 35: ...on system uniboards which are indicative of potential processor attach issues Another term you may see used is CVTM Core Voltage Telemetry Monitor v4u 6800a sc0 SC showlogs Jan 01 03 10 46 roc2s3 Dom...

Страница 36: ...owing commands refer to the Sun Fire 3800 6800 Troubleshooting Manual 805 7364 xx clearerrorbuffer clear the contents of the error buffer showerrorbuffer show the contents of the error buffer testinte...

Страница 37: ...ce manual failover to the other SC y do not prompt for confirmation n do not execute command if confirmation is requested h display this help message sc1 4800a sc setfailover force SC SSC1 Spare Syste...

Страница 38: ...the SC Starting with firmware 5 12 we poll the DX and DCDS ASICs for parity errors This requires a JTAG scan since these ASICs don t have console bus access If you press the reset button in the middle...

Страница 39: ...s 8 KBytes of serial electrically erasable programmable read only memory SEEPROM installed into all FRUs This SEEPROM is split into two sections One is read only static and the other is read write dyn...

Страница 40: ...Incorporates six media access controller MAC addresses for the F6800 and four MAC addresses for F3800 F4800 and F4810 platform and component power on hours The ID board is considered a single FRU If t...

Страница 41: ...ower assemblies is defective platform Total Number of Fan Trays Minimum Number of Fan Trays F6800 Four fan trays two in the front FT1 and FT3 and in the rear FT0 and FT2 One fan tray front FT1 and two...

Страница 42: ...will give the best availability The Sun Fire platforms offer hot swappable and redundant N 1 power supplies Power supplies are interchangeable among the F6800 and F4810 platforms The F4800 platform h...

Страница 43: ...Fire 6800 The F6800 platform has two DC power grids Grid 0 and Grid 1 The DC power supply assignments are as follows Power Grid 0 consists of power supplies PS0 PS1 and PS2 Power Grid 1 consists of p...

Страница 44: ...stem controllers There are three light emitting diodes LEDs The three LEDs are color coded green amber and amber Each LED is described below Name Color and Symbol On Off Activated green The board is a...

Страница 45: ...on Do not connect the two RTS s within an RTU to the same supply This is less reliable than having one connection only Use separate AC sources There is normally one redundant transfer unit in a Sun Fi...

Страница 46: ...have a different meaning on the RTS than on the rest of the FRUs as shown LED Position LED Color State Meaning Left Green On Off Flashing The source is present and is OK The source is not present or i...

Страница 47: ...t settings for serial port A of the system controller board are set up automatically by default and are set to 9600 baud eight data bits no parity and one stop bit Cable layout is System Controller In...

Страница 48: ...roller from the serial port of a workstation tip hardwire If you cannot use TTY Port B on the workstation s serial port you must edit the etc remote file dv dev term b br 9600 el C S Q U D ie oe D Cha...

Страница 49: ...ssage is normal for the first time you ssh into an SC On the admin ws the file HOME ssh known_hosts is created with the following details admin ws cat known_hosts 6800b sc0 127 88 169 96 ssh rsa AAAAB...

Страница 50: ...ns continue yes no no yes Connection to 6800b sc0 closed by remote host Connection to 6800b sc0 closed admin ws You will now need to remove the line in HOME ssh known_hosts pertaining to the original...

Страница 51: ...h a serial connection This way you will capture all messages from the system controller tip 9600 dev term a connected Power on the platform and the SC should run its SCPOST boot the RTOS and start the...

Страница 52: ...reserved Use is subject to license terms Sun Fire System Firmware RTOS version 38 ScApp version 5 16 0 SC POST diag level off The date is Monday February 23 2004 2 37 07 PM GMT Feb 23 14 37 08 6800b...

Страница 53: ...a 10 100BASE Ethernet RIO interface ERI controller This ERI controller can be hooked up into the network to manage the platform and domains Like any Ethernet interface the system controller requires...

Страница 54: ...NMP queries you must enable the SNMP agent and configure SNMP specific parameters Configuring the segment mode Sun Fire platforms support multiple segments partitions By default the systems are placed...

Страница 55: ...ntax of the setdate command is setdate v t time zone mmddHHMM cc yy SS Setting the Date and Time for the Shell You can set the TOD from the platform shell by using the setdate command followed by the...

Страница 56: ...that could be copied over to etc inet ntp conf and edited it provides a configuration template for a server that listens to an external hardware clock synchronizes the local clock and announces itsel...

Страница 57: ...enable remote access to the system controller select ssh or telnet If you want to use the Sun Explorer Data Collector you must select ssh or telnet Note Sun Explorer Data Collector version 4 2 does n...

Страница 58: ...SB0 SB1 SB2 SB3 SB4 SB5 IB6 IB7 IB8 IB9 COD PROC RTUs installed 0 PROC Headroom Quantity 0 to disable 4 MAX 0 PROC RTUs reserved for domain A 0 MAX 0 PROC RTUs reserved for domain B 0 MAX 0 PROC RTUs...

Страница 59: ...orm local0 notice var log messages platform local1 notice var log messages domain A local2 notice var log messages domain B local3 notice var log messages domain C local4 notice var log messages domai...

Страница 60: ...latform with the exception of the SCs which always have power through the auxiliary 48V bus 6800b sc0 SC poweron all 6800b sc0 SC poweroff all For specific HPUs 6800b sc0 SC poweroff FT0 6800b sc0 SC...

Страница 61: ...rmware indeed you do not need the Fireplane switches powered on The path to the firmware is via the console bus and bootbus The following components have flash PROMs System controller boards System bo...

Страница 62: ...SB0 FP0 Ver 09 20 2004 21 26 14 1 5 18 0 Build_14 N0 SB0 FP1 POST Yes 12 09 20 2004 21 22 14 1 5 18 0 N0 SB0 FP1 OBP Yes 12 09 20 2004 21 21 14 1 5 18 0 N0 SB0 FP1 Ver 09 20 2004 21 26 14 1 5 18 0 Bu...

Страница 63: ...sh images f is optional URL is required URL the URL of the directory containing the flash images supported protocols FTP and HTTP ftp userid password hostname path http userid password hostname path c...

Страница 64: ...d man page Edit etc passwd etc shadow To set up anonymous ftp add the following entry to the etc passwd file In this example export ftp was chosen to be the anonymous ftp area and the shell is the non...

Страница 65: ...rectory export ftp Updating directory export ftp admin ws mkdir export ftp pubandcopythepatchintoit cd export ftp pub unzip 114524 02 zip Archive 114524 02 zip creating 114524 02 inflating 114524 02 S...

Страница 66: ...ScApp will be upgraded automatically during the next boot Do you want to continue no yes Feb 16 14 36 10 6800b sc1 Platform SC Stopping all services on this SC No boards can be updated Rebooting the...

Страница 67: ...Present Getting MAC address for SSC1 MAC address is 0 3 ba 7 37 7d Hostname 6800b sc1 Address 192 77 43 115 Netmask 255 255 255 0 Attached TCP IP interface to eri unit 0 Attaching interface lo0 done G...

Страница 68: ...ving ftp v4m 5o uk sun com pub 114523 01 sgcpu flash Validating Done Current firmware version 5 12 7 New firmware version 5 16 0 Programming N0 SB0 PROM 0 Erasing Done Programming Done Verifying Done...

Страница 69: ...flash are different Proceeding with update Erasing flashprom sectors at address 0x20000000 11 11 100 Programming 11 11 100 Connecting to v4m 5o uk sun com Transferring sgsc flash via FTP 6799606 Compa...

Страница 70: ...n s Peer Reset Feb 16 14 54 13 6800b sc0 Platform SC Clock Source 75MHz Feb 16 14 54 41 6800b sc0 Platform SC Chassis is in single partition mode Feb 16 14 57 46 6800b sc0 Platform SC Main System Cont...

Страница 71: ...o clear the SC problem by pressing the reset button See page 38 A full platform shutdown is required to carry out this procedure Note Since the system controller has failed there will be no access to...

Страница 72: ...all the platform and domain configurations and passwords The system controller will be rebooted when the restore in complete The date will need to be set in the platform and each domain Do you want t...

Страница 73: ...1 6800 SC Replace the system controller using anti static procedures at all times Once SSC0 is hot plugged it will power on automatically run through SCPOST load RTOS and ScApp System controller failo...

Страница 74: ...effect immediately The old password is no longer accepted You can remove the password by pressing Return at the Enter new password and Enter new password again prompts To set the password you see the...

Страница 75: ...sc0 SC setdefaults You are about to reset all configuration data to default values All domain configurations ACLs passwords data buffers network settings and SSH host keys will be lost The system con...

Страница 76: ...le from service mode showcodlicense showcodusage showcomponent showdate showdomain showescape showenvironment showerrorbuffer showfailover showfru showkeyswitch showlogs showplatform showresetstate Ac...

Страница 77: ...ch running its own Solaris Operating Environment The system controller provides a shell interface for each defined domain to perform administrative and servicing tasks This shell is called the domain...

Страница 78: ...ment 0 RP2 RP3 constitute segment 1 For the F3800 F4800 and F4810 platforms RP0 constitutes segment 0 RP2 constitutes segment 1 All connections between the Fireplane switch boards of one segment and o...

Страница 79: ...wo domains A C F4800 One segment one domain A One segment two domains A B Two segments two domains A C F4810 One segment one domain A One segment two domains A B Two segments two domains A C F6800 One...

Страница 80: ...r and are isolated on the Sun Fireplane interconnect When two domains share a segment they each get half the address bandwidth of a full system bus When only one domain is in a segment it uses the ful...

Страница 81: ...0 SB1 On CPU Board Assigned Not tested A N0 SB2 On CPU Board Assigned Not tested A N0 SB3 On CPU Board Assigned Not tested A N0 IB6 On PCI I O Board Assigned Not tested A N0 IB7 On PCI I O Board Assig...

Страница 82: ...IB6 On PCI I O Board Assigned Not tested A N0 IB7 On PCI I O Board Assigned Not tested C N0 IB8 On PCI I O Board Assigned Not tested A N0 IB9 On PCI I O Board Assigned Not tested C 6800b sc0 SC Cauti...

Страница 83: ...ror level max interleave scope within board interleave mode optimal reboot on error true hang policy notify reset OBP use nvramrc OBP default true OBP auto boot OBP default true OBP error reset recove...

Страница 84: ...leave mode optimal reboot on error true hang policy reset OBP use nvramrc true OBP auto boot true OBP error reset recovery sync MAC Address HostID Domain C 08 00 20 d8 ab 62 80d8ab62 Loghosts Loghost...

Страница 85: ...rmission to add or delete boards Configuring ACLs The ACLs for each domain can be set up using the setupplatform shell command Prefixing a slot name with a r removes the board from the list Prefixing...

Страница 86: ...ormation There are three system controller commands used to administer the system controller s configuration data They are dumpconfig restoreconfig setdefaults Note It is NOT SUPPORTED to move the TOD...

Страница 87: ...data URL the directory to store the data files supported protocol FTP ftp userid password hostname path h display this help message 6800b sc0 SC restoreconfig Command 6800b sc0 SC help restoreconfig...

Страница 88: ...dumps sc0 4800a nvci Created ftp root root 172 16 40 5 SunFire dumps sc0 4800a tod sc0 4800a SC restoreconfig f ftp beej abc123 172 16 40 5 SunFire dumps This will restore all the platform and domain...

Страница 89: ...power mode which allows you to remove the boards from the system The domain is not initialized at system power up on Powers on and initializes the domain The system controller brings the domain into...

Страница 90: ...00 N0 SB4 P0 Copyright 2001 2004 Sun Microsystems Inc All rights reserved N0 SB4 P0 Use is subject to license terms N0 SB4 P0 Subtest Setting Fireplane Config Registers for aid 0x10 N0 SB4 P0 Subtest...

Страница 91: ...N0 SB4 P0 Subtest I Cache Branch Predict Array Test N0 SB4 P1 Subtest I Cache Branch Predict Array Test N0 SB4 P0 Subtest I Cache Initialization N0 SB4 P1 Subtest I Cache Initialization N0 SB4 P0 Sub...

Страница 92: ...N0 SB4 P1 Subtest 4M DTLB TAG Test N0 SB4 P0 Subtest 8K DTLB TAG Test N0 SB4 P1 Subtest 8K DTLB TAG Test N0 SB4 P0 Subtest 4M ITLB RAM Test N0 SB4 P1 Subtest 4M ITLB RAM Test N0 SB4 P0 Subtest 8K ITL...

Страница 93: ...g Memory Registers Tests N0 SB4 P0 Subtest Disable Memory Controllers N0 SB4 P1 Subtest Disable Memory Controllers N0 SB4 P0 Subtest Mem Addr Control Reg Test N0 SB4 P1 Subtest Mem Addr Control Reg Te...

Страница 94: ...4 P1 Subtest D Cache Functional N0 SB4 P0 Subtest D Cache Parity Functional N0 SB4 P1 Subtest D Cache Parity Functional N0 SB4 P0 Subtest D Cache Parity Tag Test N0 SB4 P1 Subtest D Cache Parity Tag T...

Страница 95: ...SB4 P1 Subtest MTAG ECC errors test N0 SB4 P0 Subtest SYSTEM ECC errors test N0 SB4 P1 Subtest SYSTEM ECC errors test N0 SB4 P0 Subtest Ecache Tag ECC errors test N0 SB4 P1 Subtest Ecache Tag ECC err...

Страница 96: ...oopback Tests for aid 0x1d N0 SB4 P0 Subtest PCI IO Controller block DMA loopback Tests for aid 0x1d N0 SB4 P0 Subtest PCI IO Controller Interrupt Tests for aid 0x1d N0 SB4 P0 Subtest PCI IO Controlle...

Страница 97: ...eeded N0 SB4 P1 DCB_ENTER_OBP command succeeded Entering OBP Sun Fire 6800 OpenFirmware version 5 16 0 12 24 03 09 54 Copyright 2001 2004 Sun Microsystems Inc All rights reserved Use is subject to lic...

Страница 98: ...t N0 SB4 P3 B0 L2 On blacklist N0 SB4 P3 B1 L3 On blacklist Board 8 Type PCI IO port 28 Status Pass Type PCI IO port 29 Status Pass Type PCI IO 10 ok probe scsi all ssm 0 0 pci 1d 700000 SUNW qlc 3 ss...

Страница 99: ...ault reset uses an externally initiated reset xir to reset the processors in the domain showresetstate If error reset recovery none you have an opportunity to gather reset states using the domain shel...

Страница 100: ...tion You can have a number of platform shells active but only one console connection Before doing the following make sure no one is using the console 6800b sc0 SC console a Connection refused console...

Страница 101: ...e If you are connected to the system controller using a tip session use the command sequence to move from the Solaris Operating Environment or OpenBoot PROM to the system controller domain shell Refer...

Страница 102: ...s a platform shell command 6800b sc0 SC showescape 6800b sc0 SC Change the escape sequence using the setescape command setescape 6800b sc0 SC help setescape setescape set system controller escape sequ...

Страница 103: ...connected to the schizos as pci 1 pci 2 pci 3 This is misleading This will only be the case for certain cards e g qfe sunswift A PCI Single FC Host Adapter in slot 0 for example will be qlc 1 Refer t...

Страница 104: ...scsi 3 disk block ssm 0 0 pci 18 700000 SUNW hme 2 1 network ssm 0 0 pci 18 700000 pci108e 1000 2 ssm 0 0 pci 18 700000 pci 1 pci ssm 0 0 pci 18 700000 pci 1 SUNW isptwo 4 scsi ssm 0 0 pci 18 700000 p...

Страница 105: ...x Refer to the tables on the next two pages for AIDs Node Mapping The node identifier for standalone Sun Fire domains is always 0 Node identifiers other than 0 will be used when wildcat comes online F...

Страница 106: ...ackets I O Mapping When mapping an I O device tree entry to a physical component in the system there are up to six nodes in the device tree that must be considered Node ID 0 for standalone Sun Fire do...

Страница 107: ...00 pci 1 SUNW hme 0 1 ssm 0 0 pci 19 600000 pci 1 SUNW qfe 2 1 ssm 0 0 pci 18 600000 SUNW qlc 1 fp 0 0 Schizo AIDs hex in brackets Schizo PCI Bus Offset Bus A offset 600000 Provides 66 33 MHz PCI bus...

Страница 108: ...ed Enterprise Services Eight Slot PCI I O Assembly Slot Assignments Logical layout as above physical layout as below pci 1 Slot 0 pci 2 Slot 1 pci 3 Slot 2 pci 18 700000 Schizo 0 pci 18 600000 pci 19...

Страница 109: ...erved Enterprise Services Six Slot cPCI I O Assembly Slot Assignments Logical layout as above physical layout as below pci 1 Slot 0 pci 1 Slot 1 pci 1 Slot 2 pci 18 600000 Schizo 0 pci 18 700000 pci 1...

Страница 110: ...vice Sun Microsystems Inc All Rights Reserved Enterprise Services Four Slot cPCI I O Assembly Slot Assignments Logical layout as above physical layout as below pci 1 Slot 0 pci 1 Slot 1 pci 1 Slot 2 p...

Страница 111: ...defaults at the domain ok prompt sc0 4800a A setdefaults Do you want to restore the default values now no yes Feb 23 07 24 55 sc0 4800a Domain A SC Setting defaults for domain A sc0 4800a A 6800b sc0...

Страница 112: ...false auto boot timeout 512 512 scsi initiator id 7 7 powerfail time 0 0 fcode debug true true output device sgc sgcn input device sgc sgcn load base 0x4000 0x4000 boot command boot boot auto boot tr...

Страница 113: ...in in effect even after a power cycle Caution Adjust configuration variables with caution These NVCI variables determine the startup routine of the system so their configuration if incorrect can cause...

Страница 114: ...8 700000 pci 1 SUNW isptwo 4 sd 0 0 disk1 ssm 0 0 pci 18 700000 pci 1 SUNW isptwo 4 sd 1 0 disk2 ssm 0 0 pci 18 700000 pci 1 SUNW isptwo 4 sd 2 0 disk3 ssm 0 0 pci 18 700000 pci 1 SUNW isptwo 4 sd 3 0...

Страница 115: ...sk ssm 0 0 pci 1a 700000 pci 1 SUNW isptwo 4 sd 0 0 xnet ssm 0 0 pci 1a 700000 pci 1 SUNW hme 0 1 diskc ssm 0 0 pci 1c 700000 pci 1 SUNW isptwo 4 sd 0 0 netc ssm 0 0 pci 1c 700000 pci 1 SUNW hme cdrom...

Страница 116: ...inID A ADInfo 1 SCAPP 15 0 Time Fri May 02 14 51 44 GMT 01 00 2003 FRU List Count 2 FRU PN 5014953 FRU SN 001494 FRU LOC RP0 FRU PN 5014362 FRU SN 015432 FRU LOC N0 SB0 Recommended Action Service acti...

Страница 117: ...ed unusable unlicensed failed or disabled board N0 SB4 May 02 14 54 54 sc0 Domain A SC No usable Cpu board in domain setkeyswitch operation did not complete keyswitch is standby Note There is no manua...

Страница 118: ...ory E cache 8 MB R freq 750 MHz A freq 750 MHz port 3 Status Pass Type CPU Memory E cache 8 MB R freq 750 MHz A freq 750 MHz Board 2 Type CPU Memory port 10 Status Pass Type CPU Memory E cache 8 MB R...

Страница 119: ...Status RP0 Suspect N0 SB0 Suspect N0 SB2 Suspect N0 SB4 Suspect sc0 SC service service sc0 SC showerrbuffer ErrorData 0 Date Fri May 02 14 51 44 GMT 01 00 2003 Device partition0 domain0 SB0 ar0 ErrorI...

Страница 120: ...rrorData 6 Date Fri May 02 14 52 16 GMT 01 00 2003 Device partition0 domain0 SB2 ar0 ErrorID 0x10421009 Register SafariPortError9 0x290 0x00000001 AdrPErr 00 00 0x1 Address parity error ErrorData 7 Da...

Страница 121: ...rrors on their interconnect to RP0 this is my suspect FRU Re assigning HostID MAC Address I want to bring up my domain but I don t want to use RP0 I have software which is hostid licensed At 5 15 x an...

Страница 122: ...ode Configure chassis for single or dual partition mode single dual sc0 SC deleteboard sb0 sb2 sb4 ib6 ib8 sc0 SC addboard d c sb0 sb2 sb4 ib6 ib8 sc0 SC showboard Slot Pwr Component Type State Status...

Страница 123: ...ff ffffffff Domain C 08 00 20 d8 86 b3 80d886b3 Domain D ff ff ff ff ff ff ffffffff SSC0 08 00 20 d8 86 b7 80d886b7 SSC1 08 00 20 d8 86 b8 80d886b8 System Serial Number 105M2F39 Chassis HostID 80d886b...

Страница 124: ...86b4 Domain C ff ff ff ff ff ff ffffffff Domain D ff ff ff ff ff ff ffffffff SSC0 08 00 20 d8 86 b7 80d886b7 SSC1 08 00 20 d8 86 b8 80d886b8 System Serial Number 105M2F39 sc0 SC Re setting component h...

Страница 125: ...Auto diagnosis Engine ADE Case Study Sun Confidential Internal Only 125 SunService Sun Microsystems Inc All Rights Reserved Enterprise Services...

Страница 126: ...Auto diagnosis Engine ADE Case Study Sun Confidential Internal Only 126 Sun Fire 3800 6800 Quick Reference Guide SunService Sun Microsystems Inc All Rights Reserved Enterprise Services...