6-2 Parameter-setting according to the selected function (Dynamic Slipping or Kinematic Linkage Breaking)
and mounting configuration :
SIDEOS N°1
SIDEOS N°2
Configuration
Encoder N°1
Encoder N°2
Kinematic linkage breaking
Kinematic linkage breaking
Drum
Drum
Drum
Motor
Kinematic linkage breaking
Dynamic Slipping
Drum
Motor
Dynamic Slipping
Dynamic Slipping
Drum
Drum
PARAMETERS
KINEMATIC LINKAGE BREAKING
DYNAMIC SLIPPING
Setting
Setting
VER
N/A
CL
French / English
NC
Pulses number / encoder N°1
Pulses number / encoder N°2
NS
Nominal speed detected by encoder N°1 in rpm
Nominal speed detected by encoder N°2 in rpm
DT
Deceleration time of the installation to pass from the nominal speed to the stop
VS
Necessary number of encoder pulses to confirm the overspeed output triggering
SP1
0
SP2
Hoisting Low Speed detected by encoder N°1 +10% (rpm)
Hoisting Low Speed detected by encoder N°2 +10% (rpm)
SP3
Hoisting High Speed detected by encoder N°1 +10% (rpm)
Hoisting High Speed detected by encoder N°2 +10% (rpm)
RC
Off : Inactive
Off : Inactive
DS
10 %
0%
TS
Speed : Input of a speed signal.
CW : Encoder rotation = clockwise
CCW : Encoder rotation = counter-clockwise
PARAMETERS
DETAILS FOR SETTING
NC
The selected encoder will deliver a frequency < 1000Hz at nominal speed otherwise the option of encoder frequency
divider will be selected.
VS
The corresponding angle of the configured pulses number will be > mechanical clearance
The validation angle will be = VS x (360/NC) (Slipping).
The validation time will be = (60xVS) / (NC x Triggering speed)
SP2
Will be = SP3 if no hoisting Low Speed, KGV input will not be wired
RC
Will be set on ON if the 2 SIDEOS One monitor the Dynamic Slipping
The minimum speed allowed during a Start order will be > 0.2Hz at the encoder
DS
Setting of the maximum speed difference in % of the nominal speed (NS)
for the Kinematic Linkage Breaking function
CW/CCW
Rotation direction by watching the encoder axis from the front during the hoisting descent