Repairing the knitting machine
7
Needle selection shifting 7.6
382
7.6.3
Reset reference values of impulse sensor, carry out
carriage reference run
Before determining the new values you have to delete the "old" values of
the impulse sensors.
1. Call up the "Service" menu from the "Main menu".
2. Call up "Basic Settings" menu.
3. Call up the "Machine parameters" window.
4. Call up "Additional function keys".
5. Call up the "Machine parameters 2" window.
6. Select all impulse sensors (activate control box). On a tandem machine
there are four impulse sensors.
7. Confirm input tapping on the (1) key.
8. You will be asked whether the values are to be deleted. Confirm this
message with "OK".
The values are deleted.
9. Carry out carriage reference run.
Key
Function
Call up the "Service" menu
Call up the "Basic settings" menu
Call up "Machine parameters" window
Call up "Additional function keys"
Call up "Machine parameters 2" window
Keys for deleting the reference values
Содержание CMS 730 S
Страница 12: ...8 ...
Страница 58: ...Description of knitting machine 2 Display and operating elements 2 8 54 ...
Страница 110: ...Producing with the knitting machine 3 Starting the machine after a fault 3 6 106 ...
Страница 390: ...Repairing the knitting machine 7 Needle selection shifting 7 6 386 ...
Страница 444: ...Yarns and stitch tension 9 Conversion table 9 4 440 ...
Страница 460: ...Machine Management Tools 10 Send email directly from the machine 10 4 456 ...
Страница 468: ...Key word directory 11 464 ...