![Stoll CMS 730 S Скачать руководство пользователя страница 164](http://html1.mh-extra.com/html/stoll/cms-730-s/cms-730-s_operating-instructions-manual_1381793164.webp)
Adjusting knitting machine
4
Advanced adjustments 4.2
160
4.2.1
Switching on and off aggregates
"Machine settings" window
Key
Function
Call up the "Machine settings" window.
Keys for calling up the "Machine settings" window
Explanation
1
Switch on or off lighting in machine area
2
Switch fabric sensors on and off (not in the case of machines with comb take-
down)
3
Switching right or left feed wheel on or off.
If the feed wheel is not required, we recommend switching it off. This saves
energy.
4
Switch fluff absorption on or off.
The needle beds in the knitting area are vacuumed off with the fluff absorption
automatically. This does not interrupt ongoing knitting. We recommend
switching on the fluff absorption permanently.
The settings for the fluff absorption always remain saved, even when the
operating system is loaded again.
Interval
Periodic switch on and off of the suction device.
After n courses: Number of courses without suction (1
course = 2 rows)
For n courses: Number of courses with suction
Stroke
"optimised": The cleaning row is carried out only in SEN
area.
"maximum": The cleaning row is carried out over the
entire needle bed.
Содержание CMS 730 S
Страница 12: ...8 ...
Страница 58: ...Description of knitting machine 2 Display and operating elements 2 8 54 ...
Страница 110: ...Producing with the knitting machine 3 Starting the machine after a fault 3 6 106 ...
Страница 390: ...Repairing the knitting machine 7 Needle selection shifting 7 6 386 ...
Страница 444: ...Yarns and stitch tension 9 Conversion table 9 4 440 ...
Страница 460: ...Machine Management Tools 10 Send email directly from the machine 10 4 456 ...
Страница 468: ...Key word directory 11 464 ...