![Stoll CMS 730 S Скачать руководство пользователя страница 108](http://html1.mh-extra.com/html/stoll/cms-730-s/cms-730-s_operating-instructions-manual_1381793108.webp)
Producing with the knitting machine
3
Starting the machine after a fault 3.6
104
3.6.2
Suppressing error messages
If, for example, a change is made to a knitting program and an error
message is present, the knitting program or other windows are covered by
the current error message. This may interrupt your work. To prevent this
from happening, the error message can be suppressed. Only the display on
the touch screen is suppressed, not the stop motion of the knitting machine.
Suppressing error messages
1. If an error message is displayed, call up the "Additional function keys"
button.
Suppressing error messages
Key
Function
Call up "Additional function keys"
Suppress error messages ("Activating setting-up operation")
Returning to the previous window
"Setting-up operation active" symbol
Enabling error messages again ("Deactivating setting-up
operation")
Keys for suppressing error messages