6.2.2 Antenna and ODU parameter configuration
The STM SatLink Terminal is normally pre-configured to be used together with the STM SatLink 403x
Transceiver. The CLI command
odu show
will show the ODU configuration with the two parameters,
ODU transmitter type and ODU receiver type, both set to STM SatLink 403x.
It is possible to configure the STM SatLink Terminal to operate together with other transmitters and
receivers than SatLink 403x. The valid ODU transmitters (BUC) are listed in Table 7 and the valid ODU
receivers (LNB) are listed in Table 9 (the list is also available using the CLI help command
? odu txtype
)
.
Choosing the ODU transmitter to be STM SatLink 403x will automatically lock the
ODU receiver type to STM SatLink 403x.
Please make sure that the correct ODU transmitter (BUC) type is selected according to the table below as
the return link communication will otherwise not work.
ODU
Transmitter #
(type)
ODU Transmitter (BUC)
STM Product Number
(P/N)
HW Revision
Ku-band
106546 (SatLink 4035)
All
11
STM SatLink 403x
104804 (SatLink 4033)
All
30
Invacom TUL-204
104041
All
45
JRC NJT5017F
All
C-band
80
JRC NJT5652
105268
All
81
JRC NJT5656
105269
All
85
Norsat 3050XPTF
105271
All
92
Zinwell ZTX-C3300F
105701
All
90
Zinwell ZTX-C3301F
105276
All
93
Zinwell ZTX-C3700F
105700
All
91
Zinwell ZTX-C3701F
105274
All
Table 7: Overview of supported ODU transmitters (BUCs)
To configure use of an ODU transmitter (BUC) listed in the table above, please enter the CLI command
odu txtype <type>
where
type
is the number from the first column in the table above.
Example:
# odu txtype 45
selects the JRC NJT5017F transmitter. Use the command
odu show
to view the ODU configuration
parameters.