Hydraulically controlled LiftRunner system (if present)
CAUTION
Only use suitable trailers that have been authorised
by the truck manufacturer.
Strictly adhere to the instructions provided by the
trailer manufacturer.
The Liftrunner system is optional. This system
allows the operator to lift and lower the trailer
after adequately connecting the trailer to the
tow tractor.
The following points are explained below:
●
Care and precautions to be followed
●
Instructions on how to hydraulically connect
the tow tractor to the trailer
●
Explanation of operation and controls
●
Instructions on how to hydraulically discon-
nect the tow tractor from the trailer
DANGER
Risk of oil splashing and injury.
Do not connect or disconnect the trailer pipe to the
quick-release coupling (1) when the tow tractor is
running. The truck should be turned off.
Do not connect or disconnect the trailer pipe to the
quick-release coupling (1) if the trailer is not in the
lowered position. Check that there are no people
near the trailer. Then lower the trailer.
Climbing on the tow tractor if someone is working on
the hydraulic connection between the tow tractor and
the trailer is forbidden. Do not connect the pipe to the
tow tractor if there are people on the tow tractor.
DANGER
Risk of crushing the trailer and the operator falling.
Climbing and walking on the trailers is forbidden.
NOTE
It is possible to configure the operation of the
trailer as follows: The tow tractor will not move
until the trailer reaches its maximum height.
For more information, please contact your au-
thorised technical assistance centre.
Connecting the trailer to the LiftRunner
system
–
Park the tow tractor safely on a flat surface.
–
Turn the switch to position (B) to turn off the
LiftRunner system.
–
Turn off the truck.
–
Climb down from the tow tractor and con-
nect the hydraulic fitting of the trailer to the
quick-release coupling (1) at the rear of the
tow tractor.
Information regarding the quick-release cou-
pling (1):
●
The theoretical maximum capacity that can
be supplied to the quick-release coupling
(1) varies between 5 l/min and 9 l/min ac-
cording to the load present on the trailers.
●
The theoretical maximum pressure that can
be supplied by the pump to the quick-re-
lease coupling is approximately 180 bar.
●
The quick-release coupling (1) is female
and 3/8".
Use
4
LiftRunner (optional)
180
45878043344 EN - 11/2021 - 12
Содержание LTX 50
Страница 2: ......
Страница 4: ......
Страница 11: ...1 Introduction ...
Страница 23: ...2 Safety ...
Страница 34: ...Safety 2 Safety devices 24 45878043344 EN 11 2021 12 ...
Страница 35: ...3 Overview ...
Страница 45: ...Front pivot wheels 24 Storage compartment 25 Overview 3 General overview LTX T 35 45878043344 EN 11 2021 12 ...
Страница 47: ...Anti shearing guard grille 24 Ballasts 25 Overview 3 General overview LTX FF 37 45878043344 EN 11 2021 12 ...
Страница 61: ...on the following pages that describes the la bel Overview 3 Markings 51 45878043344 EN 11 2021 12 ...
Страница 109: ...4 Use ...
Страница 199: ...5 Maintenance ...
Страница 219: ...6 Technical data ...
Страница 282: ...Technical data 6 Oil and lubricant tables 272 45878043344 EN 11 2021 12 ...
Страница 285: ......
Страница 286: ...STILL GmbH 45878043344 EN 11 2021 12 ...