8
S10P Series www.stenner.com
Item Number
Pump
Turndown
Turndown
Gallons
Gallons
Ounces
Ounces
Pressure
Prefix
Tube
Ratio
10 PPG
per Day
per Hour
per Hour
per Minute
Max. psi
S3P01
1
10:1
4:1
5.0
0.21
27.0
0.44
100
S3P02
2
10:1
4:1
17.0
0.71
91.0
1.51
100
S3P06
6
10:1
4:1
30.0
1.25
160.0
2.67
100
NOTICE:
The information within this chart is solely intended for use as a guide. The output data is an approximation based on
pumping water under a controlled testing environment. Many variables can affect the output of the pump. Stenner Pump
Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
FLOW RATE OUTPUTS
Approximate Maximum Outputs @ 50/60Hz
Item Number
Pump
Turndown
Turndown
Liters
Liters
Milliliters
Milliliters
Pressure
Prefix
Tube
Ratio
10 PPG
per Day
per Hour
per Hour
per Minute
Max. bar
S3P01
1
10:1
4:1
19.0
0.79
789.00
13.0
6.9
S3P02
2
10:1
4:1
64.0
2.68
2681.00
45.0
6.9
S3P06
6
10:1
4:1
114.0
4.73
4732.00
79.0
6.9
Approximate Maximum Outputs @ 50/60Hz
GALLONS & OUNCES