42
S10P Series www.stenner.com
TUBE REPLACEMENT
continued
6.
Collapse the roller assembly. Hold the pump
securely, use the tube housing cover as a tool
and quickly (snap) rotate the cover
counterclockwise to collapse the roller assembly.
The tube will no longer be pressed against the
tube housing wall.
E
7.
Remove and discard the pump tube.
F
8.
Remove the roller assembly and housing. Set
them aside to re-install later.
9.
Use a non-citrus all-purpose cleaner to clean
chemical residue from all pump components.
10.
Check the housing for cracks. Replace if cracked.
11.
Ensure the rollers turn freely. Replace the roller
assembly if the rollers are seized or worn or if
there is a reduction or lack of output from the
pump.
G
12.
Reinstall clean tube housing.
13.
Apply AquaShield
™
to the shaft tip.
14.
Install the roller assembly.
E
Collapse roller assembly
F
Remove tube
G
Check rollers
REMOVE THE PUMP TUBE