INSTALLATION
continued
MOUNT PUMP
Recommended mounting is vertical with pump head pointed downward or horizontal
sitting on motor base.
Select a dry location (to avoid water intrusion and pump damage) above the
solution tank. Best recommended location is above the solution tank in a vertical
position with the pump head pointed downward.
To prevent pump damage in the event of a pump tube leak, never mount the pump
vertically with the pump head up.
To avoid chemical damage from fumes, DO NOT mount pump directly over an open
solution tank. Keep tank covered.
Avoid flooded suction or pump mounted lower than the solution container. Draw
solution from the top of the tank. Pump can run dry without damage. If pump is
installed with a flooded suction, a shut-off valve or other device must be provided to
stop flow to pump during service.
Provide 8" clearance to allow pump removal.
To prevent damage, verify with a volt meter that the receptacle voltage corresponds
with the pump voltage.
After installation and after the settings are adjusted, be sure to tighten the screw on
the cover of the control panel.
1.
Use the mounting bracket as a template to drill pilot holes in mounting location.
2.
Secure bracket with fasteners or wall anchors. Slide pump into bracket.
Pump Head
Wall Mounting Bracket