44
S10P Series www.stenner.com
8.
Hold the pump securely. Use the cover as a tool
and quickly (snap) rotate the roller assembly
clockwise to expand the roller assembly. The tube
will be pressed against the tube housing wall.
M
9.
Apply a small amount of AquaShield
™
to the cover
bushing ONLY. DO NOT lubricate the pump tube.
N
10.
Place the tube housing cover (feet first) on the tube
housing, affix the front of the latches to the cover lip
and then press the latches back to secure. Be sure
the cover is seated with the sleeve bearing on the
shaft and is flush with the housing before latching.
Cover Bushing
M
Expand roller assembly
N
Apply Aquashield
™
to cover bushing
INSTALL THE TUBE/EXPAND THE ROLLER ASSEMBLY
continued
IMPORTANT: THE ROLLER ASSEMBLY MUST BE EXPANDED
so the tube is pressed
against the tube housing wall.
TUBE REPLACEMENT
continued
1.
Lift the latch located between the tube fittings,
leaving the end of the latch engaged with the lip on
the tube housing cover. Leave the latch on the
opposite side engaged.
O
2.
Plug the pump in. Place the pump in PRIME mode
and turn the tube fitting on the suction side not
more than 1/8 of a turn in the direction the tube
must move.
P
3.
Do not let go of the fitting until the tube rides
approximately in the center of the rollers.
4.
Take the pump out of prime mode, let go of the
fitting, and secure the latch between the fittings.
Q
5.
Inspect the suction and discharge lines, point of
injection, and check valve duckbill for blockages.
Clean and/or replace as required.
6.
Reconnect the suction and discharge lines.
7.
Prime pump and verify operation.
8.
Place pump in desired operating mode.
CENTER THE TUBE
O
Prepare to center tube
Closed latch
Front of
latch secure
Back of
latch open
P
Center tube
Q
Secure latches
1/8 Turn
M
Expand roller assembly