20
S10P Series www.stenner.com
EXCEEDING MAXIMUM SYSTEM FLOW RATE OF 14 GPM IN
10 PPG DOSING MODE MAY LEAD TO DOSING ERRORS.
1.
Calculate the
Pump Output Percentage Setting.
Metering Pump Output Requirement (gpd) x 100
=
Pump Output Percentage Setting
Metering Pump Maximum Output (gpd)
2.
Program the
Pump Operating Mode
and the
Pump Output Percentage.
Unlock the Keypad
Press and simultaneously and hold for 5 seconds to unlock the keypad.
Pump Operating Mode
First, press and continue to hold
, then press
or
to scroll through
the modes of operation. When the display shows 10 PPG, release both buttons to select.
The operating mode is now set.
Pump Output Percentage
The pump output can be programmed from 50% to 100% in 5% increments. First,
press and continue to hold , then press
or
to adjust the output
percentage determined in #1. When the display shows the desired percent, release
both buttons to select. The percentage is now set.
MODE
%
MODE
%
50%
Example of control panel set for 50% in 10 PPG DOSING mode.
Example of control panel with keypad locked.
50%
KeYPAd LocKed
PROGRAMMING
10 PPG MODE
10 PPG
Mode
10 PPG
Mode