S10P Series www.stenner.com
20%
20%
KeYPAd LocKed
3.
Calculate the
Pump Speed Percentage.
Metering Pump Output Requirement (gpd) x 100
=
Pump Speed Percentage
Metering Pump Maximum Output (gpd)
4.
Program the
Pump Operating Mode
and the
Pump Speed Percentage.
Unlock the Keypad
Press
and
simultaneously and hold for 5 seconds to unlock the keypad.
Pump Operating Mode
First, press and continue to hold , then press
or
to scroll through the
modes of operation. When the display shows AUXILIARY, release both buttons to select.
The operating mode is now set.
Pump Speed Percentage
The pump speed can be programmed from 10% to 100% in 1% increments. First, press
and continue to hold
, then press
or
to adjust the speed percentage
determined in #3. When the display shows the desired percent, release both buttons to
select. The percentage is now set.
MODE
Example of control panel with the pump speed set for 20%.
MODE
%
%
Example of control panel with keypad locked.
AUXILIARY
Mode
AUXILIARY
Mode
PROGRAMMING
AUXILIARY MODE
continued