29
US and Canada 800.683.2378, International 904.641.1666 S10P Series
INSTALLATION
ADDITIONAL SAFETY INSTRUCTIONS
NOTICE: Indicates special instructions or general mandatory action.
Read all safety hazards before installing or servicing the pump. The pump is
designed for installation and service by properly trained personnel.
Use all required personal protective equipment when working on or near a
metering pump.
Install the pump so that it is in compliance with all national and local plumbing
and electrical codes.
Use the proper product to treat potable water systems, use only additives listed or
approved for use.
Inspect tube frequently for leakage, deterioration, or wear. Schedule a regular pump
tube maintenance change to prevent damage to pump and/or spillage.
Pump is not recommended for installation in areas where leakage can cause
personal injury or property damage.
1.
Connect signal wires as required by the installation as described in the
CONNECTION section.
2.
Plug the pump into power. The cover must be lifted to program the pump. Loosen the
display cover screw and lift the cover up. To unlock the keypad, simultaneously press
and hold and for 5 seconds.
3.
Put the pump in standby. First, press and continue to hold , then press .
4.
Program the pump for the desired operating mode and % setting, refer to
Programming Operational Modes in the manual. After programming, slide the cover
on and reinstall the screw.
NOTE: Leave the unit in standby until the signal wires are connected and the pump is
ready for priming.
MODE
%
MODE
STBY