9
US and Canada 800.683.2378, International 904.641.1666 S10P Series
MODES OF OPERATION
The S10P Series is flow activated from a water meter, control valve, flow switch or any control
equipment that responds to flow. The pump accepts a dry contact or a 12-24 VAC/VDC signal
and runs at a set time, a set speed or a set flow rate output according to the mode of
operation selected.
SECONDS
(dry contact signal)
In the Seconds mode, the pump can receives a dry (non-voltage) contact and runs for a
set time in response to receiving the contact. There are five pump operating time ranges
and the maximum time is displayed in the control panel; the run time is adjustable from
10% to 100% in 1% increments.
1 SECOND = 0.1 to 1.0
5 SECONDS = 0.5 to 5.0
10 SECONDS = 1.0 to 10.0
20 SECONDS = 2.0 to 20.0
60 SECONDS = 6.0 to 60.0
AUXILIARY
In the Auxiliary mode, the pump receives a 12-24VAC/VDC signal and runs at a set speed
for as long as it receives the signal. The pump speed is adjustable from 10% to 100% in
1% increments. If polarity is reversed when connecting a DC signal to the AUX input, the
pump will not respond to the signal.
FLOW SWITCH
In the Flow Switch mode, the pump receives a dry (non-voltage) contact from a 2 wire flow
switch and runs at the set speed for as long as it receives the dry contact. The pump speed
is adjustable from 10% to 100% in 1% increments. The connection is not polarity sensitive
(polarity is not an issue when connecting the flow switch wires).
10 PPG DOSING
The 10 PPG mode is only for process flows from 0.1 to 14.0 GPM and a 10 PPG water
meter. In the 10 PPG mode, the pump receives a dry contact from the water meter and
runs at the programmed flow rate output for each pulse. The flow rate output is adjustable
from 50% to 100% in 5% increments. The connection in not polarity sensitive.
EXCEEDING MAXIMUM SYSTEM FLOW RATE OF 14 GPM IN
10 PPG DOSING MODE MAY LEAD TO DOSING ERRORS.