27
US and Canada 800.683.2378, International 904.641.1666 S10P Series
LEAK DETECT
continued
CALIBRATE THE LEAK DETECT SENSITIVITY
page 1 of 2
TO BE INSTALLED AND MAINTAINED BY PROPERLY TRAINED
PROFESSIONAL INSTALLER ONLY. READ MANUAL & LABELS FOR ALL
SAFETY INFORMATION & INSTRUCTIONS.
Turn off water system, disable all pumps and depressurize the
system before performing installation. Always wear proper protective safety
equipment when working with metering pumps.
1.
Place the pump in STANDBY.
2.
Unplug the pump.
3.
Remove tube housing cover from the pump head.
4.
Remove the cover to access the adjustment potentiometer.
5.
Use a small flat blade screwdriver less than 3 mm and turn the potentiometer
clockwise until there is a clicking sound (approx. 25 rotations).
6.
Plug the pump in.