![Stange SE-707 Скачать руководство пользователя страница 46](http://html.mh-extra.com/html/stange/se-707/se-707_operating-manual_1359472046.webp)
Program Controller SE-707
© 2018 by STANGE Elektronik GmbH
46
Subject to technical modifications
8.1.3 Manual operation for set value and tracks (”Manual”)
Set values and digital tracks can – after selecting and operating the
“Manual” button – be manipulated by the operator even during
running program.
Set values
are directly overwritten via input window.
Digital tracks
can be set to active ( “On” ) or inactive ( “Off” ) and
remain this condition as long as they are reset to their pre-
programmed state.
ATTENTION!
Manual set values and tracks are reset to pre-programmed values in case of:
- Operating the “Auto” button or a “Auto” instruction of a control system
- Loading a new programmer into the operating memory (can be blocked in the configuration)
NOTE:
Track interlocks specified at configuration are also considered in manual operation.
8.1.4 Program curve
The program curve consists of set value curve (upper graph) and
track view (bottom graph). Further set values and/or tracks can be
displayed by operating the corresponding button.
Left next to the set value curve and the track view is displayed
which line colour corresponds to which value. The actual value of
the set value and the unit are displayed. The actual condition of
the tracks is represented by the symbols “-“ for active (On) and “/”
for inactive (Off).
Control functions (right sidebar):
Start
Program start from the beginning (from RESET or END state);
continuation of programs (from HOLD state)
→
Program start with data logger
Hold
The program is stopped
Reset
Cancel program and (re-)set to standard values
Set
Further set values are displayed
Track+
Further tracks are displayed
Jump
Jump in program
The left value scale can be adapted to the respective set value by touching the scale.