![Stange SE-707 Скачать руководство пользователя страница 166](http://html.mh-extra.com/html/stange/se-707/se-707_operating-manual_1359472166.webp)
Program Controller SE-707
© 2018 by STANGE Elektronik GmbH
166
Subject to technical modifications
Alarms
View alarm overview
View/quit alarm overview (program button / back button)
Acknowledge alarm horn
Acknowledge acoustic alarm
Acknowledge alarm
Acknowledge alarm(s) (group acknowledgement and single acknowledgement)
View alarm history
Delete alarm history
Delete alarm history
Visualisation
View visualisation
View/quit visualisation (visu button / back button)
Operate visualisation
Operate visualisation (block all elements independent from „Visu Button 1-5“.
On – appears here not. The same effect for inactive and invisible.)
Visu button 1-5
Visualisation buttons
Operation
Select operating page
Select operating page (operation button)
Program Administration
View program overview
View/quit program overview (program button / back button)
Program overview gen.
Operation general (graph, switch overview set values/tracks, sorting, ... )
Select operating program
Select operating program
View program segments
View program segments (i.e. view values/graph, but not changing)
View program loops
View program loops (
→ special s
tatus because loops can be configured away, in
button status this is evaluated correspondingly!)
Change program segments/loops
Change program overview/program segments/loops (program new/copy/delete,
change program name/number, change values, insert/copy/delete segments, copy
operating program in program archive.
Import program
Import program
Export program
Export program
Process Data
View process data
View/quit process data (process data button / back button)
View process data (AV, LV,
TOL, FV)
View process data (actual values, limit values, tolerances, formula values)
Change limit values
Change limit values (must be released in the configuration additionally)
Change tolerances
Change tolerances (must be released in the configuration additionally)
Change variable value
Change variable value (must be released in the configuration additionally)
Controller
View controller page
View/quit controller page (controller button / back button)
View controller overview
View/quit controller overview (values, PID, limit values / tolerances)
Controller overview manual value
Controller overview, input manual value (
Controller overview optimisation
Controller overview, (optimisation start/stop, input PID parameters)
Input controller limit values
Input controller limit values
Input controller tolerance
Input controller tolerance
Data Logger
View data logger
View/quit data logger (data logger button / back button)
Data logger general
Data logger general (sorting, ... )
View log data
View log data (view data, select pin group)
Administrate log data
Administrate log data (delete, export)
Import log data
Import log data
Configure logger pins
Configure logger pins
Process start
Process start
Edit batch name
Edit batch name
Edit header data
Edit header data
Edit comment text
Edit comment text