GX5000S
Page 16
8.10 OPTIONAL CMP25 ENHANCED RAM+ SECOND STATION MIC
OR VH-310 HANDSET INSTALLATION
The
GX5000S
is capable of using a
CMP25
Enhanced RAM+ mic or
VH-310
Handset to remotely control the Radio, DSC and PA/Fog functions. In addition
the
GX5000S
can operate as a full function intercom system.
1. Connect the Extension Cable to the Remote Mic eight pin connector on
the rear panel, then tighten the Cable Nut (See Figure 3).
2. Referring to Figure 3, make a 1.2” (30 mm) hole in the wall, then insert the
Extension Cable into this hole. Connect the Gasket and Mount Base to the
Extension Cable Connector using the Nut.
3. Drill the four Screw holes (approx. 2 mm) on the wall, then install the Mount-
ing Base to the wall using four screws.
4. Put the Rubber Cap on to the Nut. The installation is now complete.
NOTE
The routing cable can be cut and spliced, however care needs to be
taken when reconnecting the wires to ensure water integrity.
Before cutting the cable make sure it is not plugged into the radio. After
cutting you will notice there are the following wires:
Yellow, Green, Brown, Purple, Blue, Green, Red
Ú
, Shield
Ú
Ú
The red and shield wires are wrapped in foil. Remove the foil, and
seperate the Red and shield wires.
Figure 3. Enhanced RAM+ MIC Installation
Wall
Gasket
Mounting Bracket
Routing Cable
Cap
Nut
External Speaker Connections