Ranger S Installation and troubleshooting
34
1 Turn the dial to
ADVANCED
, use the
item selectors
to scroll to item
number
3. FloGuard,
and push the
ENTER
button.
Now you'll see this display:
2
Select
4. Flow Sensor Setup
, and push the
ENTER
button.
Now you'll see this display:
3
Select
3. Current Flow Pulses and LPM
and you'll see the current
system flow in both pulses per second and liters per minute:
Note:
The Ranger 4000 S can measure correctly up to a flow of
250 pulses per second. If your flow exceeds this you should use
a sensor that has a higher "water amount per pulse" ratio.
However, a higher frequency is to prefer over a lower one, as it
provides the most accurate measuring, so in an ideal world
your frequency closes in on 250 pulses per second without ever
exceeding it. For more information turn to
.
Содержание RANGER 4000 S