Ranger S Installation and troubleshooting
50
If the station is ok, the display will look something like this:
In this case the station is pulling a current of 238mA to keep the valve open,
which is ok since this is typically in the 200‐400 mA range.
If the station fails, the display will look something like this:
If the station is not working correctly it is typically not pulling any current
at all ‐ the current reading is 0 mA.
Note:
The number before the slash is the current on the wire
before trying to activate the station ‐ if this is much more than
zero, there could be a leak somewhere.