7.2
Carrying out the conversion
The following describes how to convert the UVR-300 universal feeder and the UVR-400
universal feeder to a different stud diameter. To convert the feeders to another stud
diameter, proceed as follows:
Adjust the step width
Replace the connection piece for the stud feed hose
Replace the outlet rail and rotate the stud retainer
Change or replace the limit stop distance plate
Please also refer to chapter "7.7 Differing work steps for UVR-400" from page
44 for the different process steps regarding the following stud dimensions:
M10, M12 and Ø 10.8.
Risks when the device is switched on
Before carrying out any conversion work, the following applies:
Turn off the mains switch (a).
Disconnect the main air supply (b) at the rear of the device.
Remove the cover (d) via the fastening screws (c) on both sides.
Note for UVR-400 universal feeder:
The cover may only be opened but not removed completely.
Figure 10: Universal feeder UVR-300 (UVR-400 is similar)