48
Operating instructions UVR-300/UVR-400 | Heinz Soyer Bolzenschweißtechnik
Replacing the connection piece for the stud feed hose and rotating the stud retainer
(UVR-400 universal feeder)
Step 9:
Insert the correct stud feed hose.
Ensure that the hose end is clean, straight and free of burrs.
Insert the hose into the connection piece until the stop.
Step 10:
Secure the stud feed hose with a hose clip (a) against accidental
loosening. Please refer to chapter
“12.2 Individual parts for the UVR-
400 conversion set (M10, M12 and Ø 10.8)
It is important that the clip (a) is completely seated on
the connector (b) before fastening.
The hose clip is sufficiently tight when the hose can
no longer be moved/turned. Do not overtighten the
hose clip to avoid pinches and damage to the hose.
The deviating conversion work is finished.