Operating instructions UVR-300/UVR-400 | Heinz Soyer Bolzenschweißtechnik
23
6.4
Special functions (potentiometer)
Under the cover cap on the front panel of the device, there are adjustment elements
for special functions.
The jumper and potentiometer have been preset at the factory and do not normally
have to be adjusted.
Figure 6: Potentiometer and jumper for special functions (feeder control)
a
Cover cap
b
J 2 jumper to switch between BMK and BMS mode.
BMK mode (preset for feeder operation): J 2 is open. In the light test
after switching on, all 6 operating displays light up and then go out
again one by one.
BMS mode: J 2 is plugged in. In the light test after switching on, all
6 operating displays light up and then go out again at the same time.
c
P 1: Feeder reload time (only in BMS mode)
After each loading process, the vibration drive reloads briefly to guarantee
the outlet is sufficiently full. The reload time can be regulated based on the
stud diameter.
Turning to the left increases the time; turning to the right shortens the time.
d
P 2: Frequency adjustment for the feeder vibration drive.