Simple Network Management Protocol (SNMP)
SNMP Commands
The organization and details of the SNMP commands
are as follows.
Organization of SNMP commands
snmp
init
sys
comm
host
trap
list
name
contact
location
list
add
clear
list
add
clear
list
switch
select
<name>
<name>
<name>
<name>
<name>
<name>
<name>
[enable_all/enable_select/disable_all]
warning
clear_warning
minor
clear_minor
major
clear_major
critical
command
status
summary
[ro/wo/rw]
<community>
<community>
[enable/disable]
[enable/disable]
[enable/disable]
[enable/disable]
[enable/disable]
[enable/disable]
[enable/disable]
[enable/disable]
[enable/disable]
[enable/disable]
[enable_trap/disable_trap]
ip_addr
ip_addr
Details of SNMP commands
(1) snmp init:
Initializes the values of the SNMP commands
resumed in nonvolatile RAM.
This command is required when the unit is powered
on for the first time after installation or software
upgrading.
The initial command values are as follows:
• snmp sys name “” (NULL)
• snmp sys contact “” (NULL)
• snmp sys location “” (NULL)
• snmp comm “public” rw enable_trap
• snmp host “” (NULL)
• snmp trap switch disable_all
• snmp trap select clear disable
• snmp trap select warning disable
• snmp trap select minor disable
• snmp trap select major disable
• snmp trap select critical disable
• snmp trap select command disable
• snmp trap select status disable
After making command settings, it is necessary to
power off and on again.
(2) snmp sys list
Shows the settings of SNMP sysName, sysContact,
and sysLocation.
(3) snmp sys name <name>
Sets SNMP sysName. The maximum length is 24
characters.
This command is resumed.
(4) snmp sys contact <name>
Sets SNMP sysContact. The maximum length is 24
characters.
This command is resumed.