List of Menus
(
In tx-rx mode
)
C101
setup (Rx)
rx_program_no
00001 to 00200 to 65535 Specifies program number for decoding.
C102
setup (Rx)
rx_packet_size
auto
Automatically recognizes input TS packet
size.
188
Sets input TS packet size to fixed 188 bytes.
204
Sets input TS packet size to fixed 204 bytes.
C111
setup (Tx)
pri_pid_base
0x0010 to 00c0 to 1ff7
Specifies the base PID for transferring
private data.
C112
*
setup (Tx)
tx_umid
off
Disables UMID.
on
Enables UMID. PID is “pri_pid_base” +0.
C113
setup (Tx)
tx_line_data1
off
Disables uncompressed line data
processing of 1st line.
on
Enables uncompressed line data
processing of 1st line.
PID is “pri_pid_base” +1.
C114
setup (Tx)
tx_line_data2
off
Disables uncompressed line data
processing of 2nd line.
on
Enables uncompressed line data
processing of 2nd line.
PID is “pri_pid_base” +1.
C115
setup (Tx)
tx_line_base
12 to 21
Specifies the line number of the
uncompressed line. This line and the
following line can be transferred as
uncompressed lines.
C116
*
setup (Tx)
tx_vanc_data
off
Disables ancillary data processing in the
vertical blanking interval.
on
Enables ancillary data processing in the
vertical blanking interval. PID is
“pri_pid_base” +2.
C117
*
setup (Tx)
tx_vanc1_did
0x 00 to ff
Specifies the DID for vertical blanking
interval ancillary data.
C118
*
setup (Tx)
tx_vanc1_sdid
0x 00 to ff
Specifies the SDID for vertical blanking
interval ancillary data.
C119
*
setup (Tx)
tx_vanc2_did
0x 00 to ff
Specifies the DID for vertical blanking
interval ancillary data.
C120
*
setup (Tx)
tx_vanc2_sdid
0x 00 to ff
Specifies the SDID for vertical blanking
interval ancillary data.
C121
setup (Tx)
tx_vitc_data
off
Disables VITC private data transfer.
on
Enables VITC private data transfer.
PID is “pri_pid_base” +3.
C124
*
setup (Tx)
tx_udata1
off
Disables getting user data1 from the UDP
port, via the MSBA-20IP.
on
Enables getting user data1 from the UDP
port, via the MSBA-20IP.
PID is “pri_pid_base” +6.
C125
*
setup (Tx)
tx_udata1_port
05000 to 09000 to 65535 Sets the UDP port No. for picking up user
data1 from the MSBA-20IP.
C126
*
setup (Tx)
tx_udata1_rate
1 to 30
Specifies rate for getting user data1 from
the MSBA-20IP.
Unit: Mbps
C127
*
setup (Tx)
tx_udata2
off
Disables getting user data 2 from the UDP
port, via the MSBA-20IP.
on
Enables getting user data 2 from the UDP
port, via the MSBA-20IP.
PID is “pri_pid_base” +7.
Item number
Category
Item
Arguments
Function